Delta VFD-L Series Drive Parameters – here you can find all parameter for programming. With the help of these parameter you can easily program drive. All list of parameter like actual signal, motor data, limit parameter and fault function.
For complete parameter list download manual
Parameter Reset | |||
0 – 02 | 10 | All parameters are reset to be factory settings | |
Display Parameter | |||
0 – 04 | 0 | Display the user-defined unit (u) | |
1 | Display the counter value (C) | ||
2 | Display the content of PLC time (1 – tt) | ||
3 | Display the DC BUS voltage (U) | ||
4 | Display the output voltage (E) | ||
Password | |||
0 – 07 | 0 | no password | |
1 | parameters are locked | ||
0 – 08 | …… | Password(enter 2 times) | |
Max Output Freq | |||
1 – 00 | …… | Hz | |
Limit | |||
01- .09 | ……s | Acc Time | |
01- . 10 | ……s | Dcc Time | |
Start Command | |||
2–00 | 0 | digital keypad | |
1 | analog signal DC 0V-10V | ||
2 | analog signal DC 4mA – 20mA | ||
3 | Potentiometer on the digital keypad | ||
4 | by RS-485 serial | ||
Operation Command | |||
2–01 | 0 | keypad | |
1 | external terminals | ||
2 | external terminals | ||
3 | RS-485 communication | ||
4 | RS-485 communication | ||
Stop Method | |||
2–02 | 0 | Ramp | |
1 | Coast | ||
Carrier Freq | |||
2–03 | 3 | 3 HZ | |
4 | 4 HZ | ||
5 | 5 HZ | ||
10 | 10 HZ |
Jog | ||
01 — 15 | …… | Jog Frequency |
04–06 | 9 | Jog Function |
01–13 | ……s | Jog Acc time |
For 2-wire or 3wire operation