ABB DCS800 Drive Parameters

ABB DCS800 Drive Parameters – here you can find all parameter for programming. With the help of these parameter you can easily program drive. All list of parameter like actual signal, motor data, limit parameter and fault function.

Simple View parameter, for complete detail parameters download parameter Manual

Motor Data
99.02……VArmature Voltage
99.03……AArmature Current
99.04……rpmBase Speed
9910……VNominal Mains Voltage
99.11……AField Current
ID Run
99.062 = FieldCurAuto (autotuning field current controller)
1 = ArmCurAuto (autotuning armature current controller)
Start/Stop
10.15DI1Field Start/Stop
10.16DI1Armature Start/Stop
10.03Not Used
10.06Not Used
10.08Not Used
10.09Not Used
1020Not Used
10.21Not Used
Speed Reference
11.032-AI1
13.031 = 0V-10V Uni
ACC/DEC Time
22.01……sacceleration time 1
22.02……sdeceleration time 1
Limits
20.01……rpmMinimum Speed
22.02……rpmMaximum Speed