ABB DCS880 Drive Parameters – here you can find all parameter for programming. With the help of these parameter you can easily program drive. All list of parameter like actual signal, motor data, limit parameter and fault function.
Simple View parameter, for complete detail parameters download manual
Parameter restore | |||
96.15 | 62: Clear | ||
Motor Data | |||
9910 | ……V | Nominal mains voltage | |
99.11 | ……A | Armature Current | |
9912 | ……V | Armature Voltage | |
99.13 | ……A | Field Current | |
99.14 | ……rpm | Base Speed/Motor Speed | |
Tuning Request | |||
9920 | 1 | Field current autotuning | |
2 | Armature current autotuning | ||
Start/Stop | |||
20.02 | DI1…DI6 | Field Start/Stop | |
20.06 | DI1…DI6 | Armature Start/Stop | |
20.04 | DI1…DI6 | OFF2 Source 1(emergency off) | |
20.05 | 1 = Off3 inactive | Emergency stop source | |
20.08 | 1 = Off2 inactive | Off2 source 2 (emergency off) | |
20.13 | Not selected | Fault reset source | |
20.34 | None; inactive | Mains contactor acknowledge source | |
Speed Reference | |||
22.11 | 4 | AI1 scaled | |
5 | AI2 scaled | ||
ACC/DCC Time | |||
23.12 | ……s | Acceleration time 1 | |
23.13 | ……s | Deceleration time 1 | |
Speed Limit | |||
30.11 | ……rpm | minimum speed | |
30.12 | ……rpm | maximum speed |