ABB DCS880 Drive Programming – all parameter, control wiring, input & output power wiring and programming video.
Here is step by step programming of drive :
Control Wiring
Parameters
Parameter restore | |||
96.15 | 62: Clear | ||
Motor Data | |||
99.10 | ……V | Nominal mains voltage | |
99.11 | ……A | Armature Current | |
9912 | ……V | Armature Voltage | |
99.13 | ……A | Field Current | |
99.14 | ……rpm | Base Speed/Motor Speed | |
Start/Stop | |||
20.02 | DI1 | Field Start/Stop | |
20.06 | DI1 | Armature Start/Stop | |
20.04 | DI1…DI6 | OFF2 Source 1(emergency off) | |
20.05 | 1 = Off3 inactive | Emergency stop source | |
20.08 | 1 = Off2 inactive | Off2 source 2 (emergency off) | |
20.13 | Not selected | Fault reset source | |
20.34 | None; inactive | Mains contactor acknowledge source | |
Speed Reference | |||
22.11 | 4 | AI1 scaled | |
ACC/DCC Time | |||
23.12 | ……s | Acceleration time 1 | |
23.13 | ……s | Deceleration time 1 | |
Speed Limit | |||
30.11 | ……rpm | minimum speed | |
30.12 | ……rpm | maximum speed |