Features
Hitachi HH100 Drive are positioned for High performance applications in industrial machinery market. HH100 drives have excellent motor control performance and EMC performance. These drives are designed for textile machines, food processing machines, ceramic process machines, plastic machines, machine tool industry, elevators, transportation equipment etc.
- More accurate motor autotuning – Accurate rotating and static motor autotuning, convenient debugging, easy operation.
- Separate Airduct: The separate air duct prevents the contaminants into the electronic parts/components and greatly improves the protective effect of the inverter.
Technical Specifications
Function | Specification | |
Input | Input Voltage (V) | AC 3ph 380 V ( -15%)~440 V (+10%) |
Input Frequency (Hz) | 47~63 Hz | |
Output | Output Voltage (V) | 0~input voltage |
Output Frequency (Hz) | 0~400 Hz | |
Output Power (kW) | 0.75~15 kW | |
Technical Control Feature | Control Mode | SVPWM, sensorless vector control |
Motor Type | Asynchronous motor | |
Speed Ratio | 1:100 (SVC) | |
Speed Control Accuracy | ±0.2% (sensorless vector control) | |
Speed Fluctuation | ±0.3%(sensorless vector control) | |
Torque Response | <50 ms (sensorless vector control) | |
Torque Control Accuracy | 10% (sensorless vector control) | |
Starting Torque | 0.5 Hz / 150% (sensorless vector control) | |
Overload Capability | 150% of rated current: 1 minute 180% of rated current: 10 seconds 200% of rated current: 1 second | |
Running Feature | Frequency Setting Method | Digital setting, analog setting, pulse frequency setting, multi-stage speed running setting, simple PLC setting, PID setting, MODBUS communication setting Realize the shifting between the set combination and set channel. |
Fault Protection | Provide over 30 fault protection functions: overcurrent, overvoltage, undervoltage, overheating, phase failure and overload, etc. | |
Peripheral Interface | Analog Input | 1 channel (Al2) 0~10 V / 0~20 mA and 1 channel (Al3) -10~10 V |
Analog Output | 2 channels (AO1, AO2) 0~10 V / 0~20 mA | |
Digital Input | 4 channels common input the MAX. frequency: 1 kHz; 1 channel high speed pulse input the MAX. frequency: 50 kHz; | |
Relay Output | 2 channels programmable relay output RO1A NO, RO1B NC, RO1C common terminal RO2A NO, RO2B NC, RO2C common terminal Contactor capability: 3A / AC 250 V | |
Others | Mountable Method | Wall mountable and flange mountable |
Temperature of the running environment | -10~50°C, derate above 40°C | |
Protective Degree | | |
Cooling | Air-cooling |
Power Ratings
Model No. | Output Power (kW) | Input Current (A) | Output Current (A) | Carrier Frequency (kHz) |
HH100-0R7-4 | 0.75 | 3.4 | 2.5 | 2~15(8) |
HH100-1R5-4 | 1.5 | 5 | 3.7 | 2~15(8) |
HH100-2R2-4 | 2.2 | 5.8 | 5 | 2~15(8) |
HH100-4R0-4 | 4 | 13.5 | 9.5 | 2~15(8) |
HH100-5R5-4 | 5.5 | 19.5 | 14 | 2~15(8) |
HH100-7R5-4 | 7.5 | 25 | 18.5 | 2~15(8) |
HH100-110-4 | 11 | 32 | 25 | 2~15(8) |
HH100-150-4 | 15 | 40 | 32 | 2~8(4) |
Remarks:
- The input current is tested when no reactor and 380 V input voltage.
- The output current is defined as the rated value when the output voltage is 380 V.