Hitachi SJ700 Drive

Hitachi SJ700 Drive – Find comprehensive resources for Hitachi SJ700 AC drives, including product catalogs, manuals, price list, programming guides, fault, alarm, warnings & software support. Get expert assistance for troubleshooting and optimization.

Hitachi SJ700 Drive image

Hitachi SJ700 series is a high-performance line of variable frequency drives (VFDs) designed for demanding industrial applications.

CatalogManual
  • High Torque Performance: The SJ700 is known for its exceptional torque capabilities, especially at low speeds. This makes it suitable for applications.
  • Robust and Reliable: Designed with features like overcurrent and overvoltage suppression to prevent tripping.
  • Position Control Function: The SJ700, with optional feedback board installed, together with an encoder-equipped motor can perform position control.
SeriesApplicable motorStarting torque
SJ7000.4 to 55kW0.3Hz/200%
75 to 132kW0.3Hz/180%
185 to 400kW0.3Hz/150%

3-phase 200V class

  Model SJ700-US Version004LFUF2007LFUF2015LFUF2022LFUF2037LFUF2055LFUF2075LFUF2110LFUF2150LFUF2185LFUF2220LFUF2300LFUF2370LFUF2450LFUF2550LFUF2
JP Version004LFF2007LFF2015LFF2022LFF2037LFF2055LFF2075LFF2110LFF2150LFF2185LFF2220LFF2300LFF2370LFF2450LFF2550LFF2
Enclosure (*1)IP20
Applicable motor (4-pole, kW(HP)) (*2)0.4(1/2)0.75(1)1.5(2)2.2(3)3.7(5)5.5(7.5)7.5(10)11(15)15(20)18.5(25)22(30)30(40)37(50)45(60)55(75)
      Output RatingsRated capacity (kVA)200V1.01.72.53.65.78.311.015.922.126.332.941.950.263.076.2
240V1.22.03.14.36.89.913.319.126.631.539.450.260.275.691.4
Rated output current (A)357.510.516.5243246647695121145182220
Overload capacity(output current)150%,60sec., 200%,3sec.
Rated output voltage (*3)3-phase (3-wire) 200 to 240V (corresponding to input voltage)
Input RatingRated input voltage (V)3-phase 200 to 240V+10%, -15%, 50/60Hz±5%
Rated input current (A)3.35.58.312182635517084105133160200242
  BrakingDynamic braking (Short-time) (*4)Built-in BRD circuit (optional resistor)External dynamic braking unit (option)
Minimum value of resistor (Ω)50503535351610107.57.55
Vibration (*5)5.9m/s2(0.6G), 10-55Hz2.9m/s2(0.3G), 10-55Hz
EMC filterBuilt-in (EN61800-3 category C3)
Zero-phase ReactorBuilt-in
Weight (lbs.)3.5(7.7)3.5(7.7)3.5(7.7)3.5(7.7)3.5(7.7)6(13.2)6(13.2)6(13.2)14(30.8)14(30.8)14(30.8)22(48.4)30(66)30(66)43(94.6)

 3-phase 400V class

  Model SJ700-European Version007HFEF2015HFEF2022HFEF2040HFEF2055HFEF2075HFEF2110HFEF2150HFEF2185HFEF2220HFEF2300HFEF2370HFEF2450HFEF2550HFEF2
US Version007HFUF2015HFUF2022HFUF2040HFUF2055HFUF2075HFUF2110HFUF2150HFUF2185HFUF2220HFUF2300HFUF2370HFUF2450HFUF2550HFUF2
JP Version007HFF2015HFF2022HFF2037HFF2055HFF2075HFF2110HFF2150HFF2185HFF2220HFF2300HFF2370HFF2450HFF2550HFF2
Enclosure (*1)IP20
Applicable motor (4-pole, kW(HP)) (*2)0.75(1)1.5(2)2.2(3)3.7(5) 4.0(5)5.5(7.5)7.5(10)11(15)15(20)18.5(25)22(30)30(40)37(50)45(60)55(75)
      Output RatingsRated capacity (kVA)400V1.72.53.66.29.713.117.322.126.333.240.151.963.077.6
480V2.03.14.37.411.615.820.726.631.539.948.262.375.693.1
Rated output current (A)2.53.85.39.0141925323848587591112
Overload capacity(output current)150%,60sec., 200%,3sec.
Rated output voltage (*3)3-phase (3-wire) 380 to 480V (corresponding to input voltage)
Input RatingRated input voltage (V)3-phase 380 to 480V +10%, -15%, 50/60Hz±5%
Rated input current (A)2.84.25.89.91723303542536483100123
  BrakingDynamic braking (Short-time) (*4)Built-in BRD circuit (optional resistor)External dynamic braking unit (option)
Minimum value of resistor (Ω)10010010070703535242420
Vibration (*5)5.9m/s2(0.6G), 10-55Hz2.9m/s2(0.3G), 10-55Hz
EMC filterBuilt-in (EN61800-3 category C3)
Zero-phase ReactorBuilt-in
Weight (lbs.)3.5(7.7)3.5(7.7)3.5(7.7)3.5(7.7)6(13.2)6(13.2)6(13.2)14(30.8)14(30.8)14(30.8)22(48.4)30(66)30(66)30(66)
  Model SJ700-European Version750HFEF2900HFEF21100HFEF21320HFEF21850HFE22200HFE23150HFE24000HFE2
US Version750HFUF2900HFUF21100HFUF21500HFUF21850HFU22200HFU23150HFU24000HFU2
JP Version750HFF2900HFF21100HFF21320HFF21850HF22200HF23150HF24000HF2
Enclosure (*1)IP00
Applicable motor (4-pole, kW(HP)) (*2)75(100)90(125)110(150)132(150)185(250)220(300)315(400)400(550)
      Output RatingsRated capacity (kVA)400V103.2121.9150.3180.1256305416554
480V123.8146.3180.4216.1308366499665
Rated output current (A)149176217260370440600800
Overload capacity(output current)150%,60sec., 200%,0.5sec.150%,60sec., 180%,0.5sec.
Rated output voltage (*3)3-phase (3-wire) 380 to 480V (corresponding to input voltage)
Input RatingRated input voltage (V)3-phase 380 to 480V +10%, -15%, 50/60Hz±5%
Rated input current (A)164194239286389455630840
  BrakingDynamic braking (Short-time) (*4)External dynamic braking unit (option)
Minimum value of resistor (Ω)
Vibration (*5)2.9m/s2(0.3G), 10-55Hz1.96m/s2(0.2G), 10-55Hz
EMC filterBuilt-in (EN61800-3 category C3)External Option
Zero-phase ReactorBuilt-inExternal Option
Weight (lbs.)60(132)60(132)80(176)80(176)140(308)145(319)210(462)360(792)
ItemsGeneral Specifications
                ControlControl methodLine to line sine wave pulse-width modulation (PWM) control
Output frequency range (*6)0.1-400.0Hz(400kW and over:0.1-120Hz)
Frequency accuracyDigital: ±0.01% of the maximum frequency, Analog: ±0.2%(25±10˚C)
Frequency resolutionDigital setting: 0.01Hz, Analog setting: (Maximum frequency)/4,000 (O terminal: 12bit 0-10V, O2 terminal: 12bit -10-+10V)
V/f characteristicsV/f optionally variable (30-400Hz of base frequency), V/f control (constant torque, reduced torque), Sensorless vector control, 0Hz domain sensorless vector control(*9), vector control (SJ-FB card option)(*9)
Speed fluctuation±0.5% (sensorless vector control)
Acceleration/deceleration time0.01-3,600sec. (Linear/curve, accel./decel. selection), Two-stage accel./decel.
  Starting TorqueSJ700 (Sensorless vector control): 200% at 0.3Hz/ 75kW and over:180% at 0.3Hz, L700 (Sensorless vector control): 150% at 0.5Hz/ 90kW and over:120% at 0.3Hz, SJ700 (0Hz domain with motor one frame size down):150% at around 0Hz/ 75kW and over: 130% at around 0Hz.
Carrier frequency rangeSJ700: 0.5-15.0kHz(185kW and over:0.5-3.0kHz)/L700: 0.5-12.0kHz(110kW and over:0.5-8.0kHz)
DC brakingPerforms at start: under set frequency at deceleration, via an external input (braking force, time, and operating frequency).
                            Input signalFrequency settingOperatorUp and Down keys
External signal*8DC 0-10V, -10-+10V (input impedance 10kΩ), 4-20mA (input impedance 100Ω)
External portSetting via RS485 communication
  Forward /reverse Start /stopOperatorStart/stop commands (forward/reverse switching by parameter setting)
External signalForward-operation start/stop commands (reverse-operation start/stop possible when relevant commands are assigned to intelligent input terminals)3-wire input possible (when relevant commands are assigned to control circuit terminals)
External portSetting via RS485 communication
                Intelligent input terminalsTerminals8 terminals, NO/NC switchable, sink logic/source logic switchable
                FunctionsReverse operation (RV), Multi-speed 1 setting (CF1), Multi-speed 2 setting (CF2), Multi-speed 3 setting (CF3), Multi-speed 4 setting (CF4), Jogging (JG), external DC braking (DB), 2nd motor control (SET), 2-stage acceleration/deceleration (2CH), free-run stop (FRS), external trip (EXT), unattended start protection (USP), commercial power supply switching (CS), software lock (SFT), analog input switching (AT), 3rd motor control (SET3), reset (RS), starting by 3-wire input (STA), stopping by 3-wire input (STP), forward/reverse switching by 3-wire input (F/R), PID disable (PID), PID integration reset (PIDC), control gain switching (CAS), acceleration by remote control (UP), deceleration by remote control (DWN), data clearance by remote control (UDC), forcible operation (OPE), Multi-speed bit 1 (SF1), Multi-speed bit 2 (SF2), Multi-speed bit 3 (SF3), Multi-speed bit 4 (SF4), Multi-speed bit 5 (SF5), Multi-speed bit 6 (SF6), Multi-speed bit 7 (SF7), overload restriction selection (OLR), torque limit selection (enabling/disabling) (TL), torque limit 1 (TRQ1), torque limit 2 (TRQ2), P/PI switching (PPI), braking confirmation (BOK)(*9), orientation (ORT)(*9), LAD cancellation (LAC), clearance of position deviation (PCLR)(*9), permission of 90˚shift phase (STAT)(*9), trigger for frequency addition (A145) (ADD), forcible-terminal operation (F-TM), permission of torque command input (ATR)(*9), cumulative power clearance (KHC), servo-on (SON)(*9), pre-excitation (FOC)(*9), general-purpose input 1 (MI1), general-purpose input 2 (MI2), general-purpose input 3 (MI3), general-purpose input 4 (MI4), general-purpose input 5 (MI5), general-purpose input 6 (MI6), general-purpose input 7 (MI7), general-purpose input 8 (MI8), analog command holding (AHD), Multistage position settings selection 1 (CP1)(*9), Multistage position settings selection 2 (CP2)(*9), Multistage position settings selection 3 (CP3)(*9), Zero-return limit function (ORL)(*9), Zero-return trigger function (ORG)(*9), Forward drive stop (FOT)(*9), reverse drive stop (ROT)(*9), Speed / position switching (SPD)(*9), Pulse counter (PCNT), Pulse counter clear (PCC), Emergency stop (EMR) ,no assignment (no)
Thermistor input1 terminal (PTC characteristics)
                Output signal              Intelligent output terminalsTerminals5 open-collector output terminals, NO/NC switchable, sink logic/source logic switchable 1 relay (1c-contact) output terminal: NO/NC switchable
            FunctionsRunning (RUN), constant-speed reached (FA1), set frequency overreached (FA2), overload notice advance signal (1) (OL), output deviation for PID control (OD), alarm signal (AL), set frequency reached (FA3), over-torque (OTQ), instantaneous power failure (IP), undervoltage (UV), torque limited (TRQ), operation time over (RNT), plug-in time over (ONT), thermal alarm signal (THM), brake release (BRK)(*9), braking error (BER)(*9), 0Hz detection signal (ZS), speed deviation maximum (DSE)(*9), positioning completed (POK)(*9), set frequency overreached 2 (FA4), set frequency reached 2 (FA5), overload notice advance signal (2) (OL2), PID feedback comparison (FBV), communication line disconnection (NDc), logical operation result 1 (LOG1), logical operation result 2 (LOG2), logical operation result 3 (LOG3), logical operation result 4 (LOG4), logical operation result 5 (LOG5), logical operation result 6 (LOG6), capacitor life warning (WAC), cooling-fan speed drop (WAF), starting contact signal (FR), heat sink overheat warning (OHF), low-current indication signal (LOC), general-purpose output 1 (M01), general-purpose output 2 (M02), general-purpose output 3 (M03), general-purpose output 4 (M04), general-purpose output 5 (M05), general-purpose output 6 (M06), inverter ready (IRDY), forward rotation (FWR), reverse rotation (RVR), major failure (MJA), window comparator O (WCO), window comparator OI (WCOI), window comparator O2 (WCO2), alarm code 0 to 3 (AC0 to AC3)
Monitor output terminalsAnalog voltage output, analog current output, pulse-string output (e.g., A-F, D-F [n-fold, pulse output only], A, T, V, P)
Monitoring on displayOutput frequency, output current, output torque, frequency conversion data, trip history, input/output terminal status, electric power, and others
        Other functionsFree V/f setting (7 breakpoints), frequency upper/lower limit, jump (center) frequency, acceleration/deceleration according to characteristic curve, manual torque boost level/breakpoint, energy-saving operation, analog meter adjustment, start frequency setting, carrier frequency adjustment, electronic thermal function (available also for free setting), external start/end frequency/frequency rate, analog input selection, retry after trip, restart after instantaneous power failure, output of various signals, starting with reduced voltage, overload restriction, initial-value setting, automatic deceleration at power failure, AVR function, fuzzy acceleration/deceleration(*9), online/offline auto-tuning, high-torque multi-motor operation (sensorless vector control of two motors by one inverter)
  Protective functionsOvercurrent protection, overvoltage protection, undervoltage protection, electronic thermal protection, temperature error protection, instantaneous power failure protection, phase loss input protection, braking-resistor overload protection, ground-fault current detection at power-on, USP error, external trip, emergency stop trip, CT error, communication error, option board error, and others
Environmental conditionsAmbient operating/storage temperature(*7)/ humidity-10-50˚C(*10) / -20-65˚C / 20-90%RH (No condensation)
LocationAltitude 1,000m or less, indoors (no corrosive gases or dust)
  OptionsDigital input expansion cardSJ-DG (4digits BCD, 16bits binary)
Feedback expansion cardSJ-FB (vector control loop speed sensor)(*9)
Network interface cardSJ-DN2(DeviceNet(TM)), SJ-PBT(PROFIBUS)
OthersEMI filters, input/output reactors, radio noize filters, braking resistors, braking units, LCR filter, communication cables

*1: The protection method conforms to JEM 1030.

*2: The applicable motor refers to Hitachi standard 3-phase motor (4-pole).

To use other motors, be sure to prevent the rated motor current (50Hz) from exceeding the rated output current of the inverter.

*3: The output voltage decreases as the main power supply voltage decreases except for the use of AVR function.

*4: Braking resistor is not integrated in the inverter. Please install optional braking resistor or dynamic braking unit when large braking torque is required.

*5: Conforms to the test method specified in JIS C 60068-2-6:2010 (IEC 60068-2-6:2007).

*6: To operate the motor beyond 50/60Hz, please consult with the motor manufacturer about the maximum allowable rotation speed.

*7: Storage temperature refers to the temperature in transportation.

*8: The frequency command is the maximum frequency at 9.8V for input voltage 0 to 10VDC,or at 19.6mA for input current 4 to 20mA.If this characteristic is not satisfactory for your application,contact your Hitachi representative.

*9: L700 series:The function is not provided.

*10: L700 series is -10 to 40℃.

*11: Please be sure to connect DC reactor attached to 4000HF.