KEB C6 Safety PLC is a crucial component in ensuring functional safety within industrial automation systems.It provides a central point for managing and monitoring all safety-related functions in the system.
The C6 Safety PLC as a safety controller and the C6 Safety I/O module handle all safety-related tasks at control level and can also be integrated into an existing EtherCAT structure. Communication is carried out via the existing EtherCAT bus with the certified Safety over EtherCAT (FSoE) safety protocol. Any FSoE slaves (for example Safety I/O modules, KEB’s drive controller with a safety module) can be operated via the Safety PLC (FSoE master).
KEB C6 Safety IO
The freely programmable Safety PLC and the Safety I/O module comply with the requirements of safety standards IEC 61508 SIL 3 and DIN EN ISO 13849-1 PLe. The safety PLC has a double-channel design and is programmed using the COMBIVIS studio 6 programming tools which include the certified functional safety modules. For the user, this means reduced development work and minimised testing and approval of the created safety application.
Highlights
- Freely programmable Safety PLC (IEC 61508 SIL3 and DIN EN ISO 13849-1 Ple)
- Certified safety function modules
- Substantial reduction in time spent on development, verification and approval of a safety application
- Programming by means of CODESYS Safety via the main controller and EtherCAT connection
Technical Data & Specification
C6 Safety PLC | |
Safety protocol | FSoE |
Safety standard | IEC 61508 SIL3 and DIN EN ISO 13849-1 PLe |
Approvals | CE, cULus, TÜV Rheinland |
Runtime system | CODESYS RT Safety |
Programming tool | CODESYS Safety integrated from COMBIVIS studio 6 V3.6.4.1 |
E-Bus power consumption | 240 mA |
Power supply | Via E-Bus connection |
Resistance to interference | EN 61000-6-2 / EN 61000-6-4 |
Resistance to vibration/shock | EN 60068-2-6 / EN 60068-2-27 |
Signal display | Status LEDs (EtherCAT, Safety, Power) |
Ambient conditions | 0° C … +55° C, IP 20 |
Housing | Aluminium carrier, exterior plastic 25 x 120 x 90 mm |
Safety IO Specifications:
C6 Safety I/O | |
Safety protocol | FSoE |
Safety standard | IEC 61508 SIL3 and DIN EN ISO 13849-1 PLe |
Number of inputs | 4 safe inputs |
Number of outputs | 2 safe outputs (IMAX = 2) |
Cycled outputs (OSSD) | 4 |
Reaction time | < 1 ms (read input, write to E-Bus) |
Fault reaction time | ≤ Watchdog time (adjustable) |
Extended diagnostics | via COE |
Signal display | LEDs per I/O: spatially assigned to the terminal point Status LEDs (EtherCAT, Safety, Power) |
E-Bus power consumption | 300 mA |
Power supply | 24 V DC (-15 % / +20 %) |
Resistance to interference | EN 61000-6-2 / EN 61000-6-4 |
Resistance to vibration/shock | EN 60068-2-6 / EN 60068-2-27 |
Approvals | CE, cULus, TÜV Rheinland |
Ambient conditions | 0° C … +55 °C, IP 20 |
Housing | Aluminium carrier, external plastic 25 x 120 x 90 mm |
Below image shows KEB C6 Safety PLC ports details:
Below image shows KEB C6 Safety IO details: