LS-Electric H100 Drive – Find comprehensive resources for LS-Electric H100 AC drives, including product catalogs, manuals, price list, programming guides, fault, alarm, warnings & software support. Get expert assistance for troubleshooting and optimization.
![LS-Electric H100 Drive image](https://click2electro.com/wp-content/uploads/2025/01/LS-Electric-H100-Drive-image.png)
The LSLV-H100 sets the standard for the drive industry. Environmentally friendly water treatment and Fan and Pump systems incorporate the outstanding energy-saving benefits of the LSLV-H100 for fans and pumps.
Features
Communication Module
- RS-485 Capability is built-in
- Modbus-RTU, Metasys N2
- BACnet MS/TP is embedded as standard
- LonWorks option can be added
Easy to Change Cooling Fan
- It is easy to change the cooling fan without opening the cover of the drive
Keypad Exclusive for HVAC
Used to issue commands, configure drive parameters, and for monitoring drive status
- HAND mode (Local, Control, Mode) or AUTO Mode (Remote Control Mode) may be selected.
- HAND Mode: Used when selecting frequency or run/stop commands.
- AUTO Mode: Drive operated using the keypad. Multifunctional terminal block and communications.
- Fault Status Monitoring
Specification Level Option (Conduit Kit)
- When the conduit option is used, the drive meets UL Enclosed Type 1 specifications
Flange Type
- If the space is too small, a heat sink can be installed outside the panel
DC Reactor
- A built-in DC reactor to improve power factors and reduce THD is installed.
- DC Reactor built-in as a standard for 400V 37~500kW
Built-in EMC Filter
A built-in EMC filter to respond to the specifications for noise reduction
- ㆍ400V 0.75~30kW Built-in as default (C3)
- ㆍ400V 37~55kW Built-in option can be selected (C3)
- 75~90kW satisfies EMC specifications even without a filter
Compliant with Global Specifications
- UL Plenum Rated (American standards for conditional fire safety)
Smart Copier
- Power-free Operation
- LED Feedback
- Parameters Read/Write
- Easy to Install
Specification
3-Phase 200V (0.75~18.5kW)
Model Name LSLV ㅁㅁㅁㅁH100-2 ㅁㅁㅁㅁ | 0008 | 0015 | 0022 | 0037 | 0055 | 0075 | 0110 | 0150 | 0185 | |
---|---|---|---|---|---|---|---|---|---|---|
Applied Motor | [HP] | TBD | 7.5 | 10 | 15 | 20 | 25 | |||
[kW] | 5.5 | 7.5 | 11 | 15 | 18.5 | |||||
Rated Output | Rated Capacity (kVA) | 8.4 | 11.4 | 16.0 | 21.3 | 26.3 | ||||
Rated Current | 22 | 30 | 42 | 56 | 69 | |||||
Output Frequency | 0~400Hz | |||||||||
Output Voltage (V) | 3-Phase 200~240V | |||||||||
Rated Input | Service Voltage (V) | 3-Phase 200~240VAC (-15%~+10%) | ||||||||
Input Frequency | 50~60Hz ( .5%) | |||||||||
Rated Current (A) | 23.7 | 32.7 | 46.4 | 62.3 | 77.2 | |||||
Weight [kg] | 3.3 | 3.3 | 3.3 | 4.6 | 7.1 |
· Motor capacity is based on use of 4-pole standard motors.
· 200V Class is for 220V and 400V Class is for 440V.
· Rated output current if limited depending on the carrier frequency (CON-04) setting
3-Phase 400V (0.75~22kW)
Model Name LSLV ㅁㅁㅁㅁH100-4 ㅁㅁㅁㅁ | 0008 | 0015 | 0022 | 0037 | 0055 | 0075 | 0110 | 0150 | 0185 | 0220 | |
---|---|---|---|---|---|---|---|---|---|---|---|
Applied Motor | [HP] | TBD | 7.5 | 10 | 15 | 20 | 25 | 30 | |||
[kW] | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | |||||
Rated Output | Rated Capacity (kVA) | 9.1 | 12.2 | 18.3 | 23 | 29.0 | 34.3 | ||||
Rated Current | 12 | 16 | 24 | 30 | 38 | 45 | |||||
Output Frequency | 0~400Hz | ||||||||||
Output Voltage (V) | 3-Phase 200~240V | ||||||||||
Rated Input | Service Voltage (V) | 3-Phase 200~240VAC (-15%~+10%) | |||||||||
Input Frequency | 50~60Hz ( .5%) | ||||||||||
Rated Current (A) | 12.2 | 17.5 | 26.5 | 33.4 | 42.5 | 50.7 | |||||
Weight [kg] | 3.3 | 3.3 | 3.4 | 4.6 | 4.8 | 7.5 |
· Motor capacity is based on use of 4-pole standard motors.
· 200V Class is for 220V and 400V Class is for 440V.
· Rated output current if limited depending on the carrier frequency (CON-04) setting
3-Phase 400V (30.0~90.0kW)
Model Name LSLV ㅁㅁㅁㅁH100-4 ㅁㅁㅁㅁ | 0300 | 0370 | 0450 | 0550 | 0750 | 0900 | |
---|---|---|---|---|---|---|---|
Applied Motor | [HP] | 40 | 50 | 60 | 75 | 100 | 125 |
[kW] | 30 | 37 | 45 | 55 | 75 | 90 | |
Rated Output | Rated Capacity (kVA) | 46.5 | 57.1 | 69.4 | 82.0 | 108.2 | 128.8 |
Rated Current | 61 | 75 | 91 | 107 | 142 | 169 | |
Output Frequency | 0~400Hz | ||||||
Output Voltage (V) | 3-Phase 380~480V | ||||||
Rated Input | Service Voltage (V) | 3-Phase 380~480VAC (-15%~+10%) | |||||
Input Frequency | 50~60Hz ( .5%) | ||||||
Rated Current (A) | 69.1 | 69.3 | 84.6 | 100.1 | 133.6 | 160.0 | |
Weight [kg] | 7.5 | 26 | 35 | 35 | 43 | 43 |
· Motor capacity is based on use of 4-pole standard motors.
· 200V Class is for 220V and 400V Class is for 440V.
· Rated output current if limited depending on the carrier frequency (CON-04) setting
3-Phase 400V (110.0~500.0kW)
Model Name LSLV ㅁㅁㅁㅁH100-4 ㅁㅁㅁㅁ | 1100 | 1320 | 1600 | 1850 | 2200 | 2500 | 3150 | 3550 | 4000 | 5000 | |
---|---|---|---|---|---|---|---|---|---|---|---|
Applied Motor | [HP] | 150 | 200 | 250 | 300 | 350 | 400 | 500 | 550 | 650 | 800 |
[kW] | 110 | 132 | 160 | 185 | 220 | 250 | 315 | 355 | 400 | 500 | |
Rated Output | Rated Capacity (kVA) | 170 | 201 | 248 | 282 | 329 | 367 | 467 | 520 | 587 | 733 |
Rated Current | 223 | 264 | 325 | 370 | 432 | 481 | 613 | 683 | 770 | 962 | |
Output Frequency | 0~400Hz | ||||||||||
Output Voltage (V) | 3-Phase 380~500V | ||||||||||
Rated Input | Service Voltage (V) | 3-Phase 380~500VAC (-15%~+10%) | |||||||||
Input Frequency | 50~60Hz ( ±5%) | ||||||||||
Rated Current (A) | 215.1 | 254.6 | 315.3 | 358.9 | 419.1 | 469.3 | 598.1 | 666.4 | 751.3 | 938.6 | |
Weight [kg] | 55.8 | 55.8 | 74.7 | 74.7 | 120.0 | 120.0 | 185.5 | 185.5 | 185.5 | 265 |
· Motor capacity is based on use of 4-pole standard motors.
· 200V Class is for 220V and 400V Class is for 440V.
· Rated output current if limited depending on the carrier frequency (CON-04) setting