LS-Electric iC5 Drive

LS-Electric iC5 Drive – Find comprehensive resources for LS-Electric iC5 AC drives, including product catalogs, manuals, price list, programming guides, fault, alarm, warnings & software support. Get expert assistance for troubleshooting and optimization.

LS-Electric iC5 Drive image

The LS-Electric iC5 Drive is a compact frequency inverter designed for single-phase power supplies. Its small size makes it suitable for applications with limited space.

CatalogManual

The LS-Electric iC5 Drive is a versatile and reliable frequency inverter that offers a combination of performance, ease of use, and compact design. Its advanced features make it a suitable choice for a wide range of applications in various industries.

  • Sensorless vector control
    The iC5 adopted the sensorless vector control algorithm, which improves not only the torque control characteristics, but the speed controllability in uncertain conditions caused by the load variation.
  • Auto Tuning
    The auto tuning algorithm in the iC5 sets the motor factors automatically that brings the traditional commissioning difficulties mainly in low speed by the load variation and the low torque generation to a settlement.
  • Highly efficient DSP chip
    The iC5 adopts a highly efficient DSP (Digital Signal Processing) chip to improve processing speed, flexibility, and stability.
  • PNP and NPN Dual Control Signal
    The iC5 provides PNP and NPN signals for outside controllers.
    It works with 24Vdc regardless of the type of PLC or control signals.
  • Communication interface, Modbus-RTU
    The iC5 provides the most popular communication interface, ModBus-RTU for remote control by the PLC or other devices.
  • PID Control
    PID process control is used in iC5 to quickly make speed corrections with a minimal amount of overshoot and oscillation for the control of flow, temperature, and pressure.

Below table show LS-Electric iC5 drive specifications:

200V Class
TypeSV004 iC5-1SV008 iC5-1SV015 iC5-1SV022 iC5-1
200V ClassMotor Rating[HP]0.5123
[kW]0.40.751.52.2
Output ratingsCapacity[kVA]0.950.953.04.5
FLA[A]2.50.953.04.5
Output frequency0 ~ 400Hz
Output voltage3 Phasde200~230V
Input ratingsVoltageSingle phase 200 ~ 230 V (±10%)
FLA[A]5.59.21621.6
Frequency50 ~ 60 Hz (± 5%)
ControlControl methodV/F control, Sersorless vector control
Frequency setting resolutionDigital reference: 0.01Hz
Analog referency: 0.06Hz/60Hz
Frequency setting resolutionDigital reference: 0.01Hz
Analog referency: 0.06Hz/60Hz
V/F ratioLinear, Square pattern, User V/F
Overload capacity1 min at 150%, 30 sec at 200% (with inverse characteristic)
Torque boostManual torque boost (0~15 adjustable), auto torque boost
Input signalOperation methodKeypad / Terminal / Communications
Frequency settingAnalog: 0~10V / 4~20mA, Digital: Keypad,
Communication: RS485 (Option)
Start signalForward, Reverse
Multi-step accel/decal time0.1~6000 sec. Max. 8 types available by multi-function terminal, Selectable accel/decel patterns : Linear, U and S
Emergency stopInterrupting the output of the drive.
JogJog operation
Fault resetReset the fault when protective function is active
Output signalOperation status & fault outputFrequency detection, Overload alarm, Stalling, Overvoltage, Undervoltage, Drive overheating, Run, Stop, Constant speed, Speed searching, Fault output ( Relay and Open collector output )
IndicatorChoose one from output frequency, current, voltage and DC voltage.(Output voltage : 0~10V )
Operation functionDC braking, Frequency limit, Frequency jump, Second function, Slip compensation, Reversing prevention, Auto restart, PID control
Protection functionsDrive tripOvervoltage, Undervoltage, Overcurrent, Drive overtemperature, Motor overtemperature, I/O phase loss, I/O mis-wiring, Overload , External device fault 1.2, Loss of speed command, Hardware fault, Communication error, CPU error
Drive alarmStall prevention, Overload alarm
Momentary power lossLess than 15 msec: keeping operation
More than 15 msec: auto restart available
Display KeypadOperation informationOutput frequency, current and voltage, Set frequency value, Operation speed, DC voltage
Trip informationDisplay the trip cause when the protection function activates. Recent 5 faults records stored
EnvironmentAmbient temperature-10 ~ 40℃
Storage temperature-20 ~ 65℃
Humidity90 %RH max (No condensing)
AtmosphereNo corrosive gas, flammable gas, oil mist or dust
Pressure70 ~ 106k Pa