  • Dual PID :When additional PID control or cascade PID control is required, dual PID provide users with various uses of the system with only iP5A.
  • Multi Motor Control : The built-in algebra control function enables an inverter to control motors without a controller so that user can take advantage of energy-saving and lower costs.
  • Sleep and Wake-Up : The built-in energy saving function makes the inverter stop automatically when the capacity is too low.
  • Pre-Heater : The built-in pre-heater function prevents motor damage and inverter break-down caused from humidity.
  • Flying Start : When the inverter drives many ventilators or when the fan in a big load system turns due to a natural displacement, iP5A operates the motor by automatically searching for the motor speed.
  • Auto energy saving :iP5A provides the auto energy saving function by an optimal flux control which minimizes energy loss caused by load change.
  • Improved Management from Instant Power-off and Power Dip Generation : During the power dip or instant power-off, which is generated by lightening, ground fault, and power-failure, loads still keep the mechanical energy and this energy flows back to inverter by regeneration. The power-failure guarantee time is extended by using this electrical character of the inverter.
  • Constant and Stable Performance (24 hours 365 days) : Regardless of outside alteration such as input voltage variation by load change or weather effect, iP5A can handle motor and load with best performance.
  • Safety Stop : When unexpected power-failure blocks the power supply, the inverter stops the motor by using energy of the load that prevents reoccurrence of accidents (Parameter setting is required).

Below table show LS-Electric iP5A Drive specifications:

3-phase 200V Class (0.75~30kW)
Model Number (SVㅁㅁㅁiP5A-2)008015022037055075110150185220300
Capacity [kVA] 1)1.93.04.66.16.112.217.522.928.233.543.8
Output
ratings
Fan or
pump load
Motor rating 2)(HP)12357.5101520253040
(kW)0.751.52.23.75.57.5111518.52230
Current [A]581216243246607488115
(110% over current)110% 1 Minute (Normal Duty)
General
load
Motor rating(HP)0.512357.51015202530
(kW)0.40.751.52.23.75.57.5111518.522
Current [A]2.5581217233344546884
(150% over current)150% 1 Minute (Heavy Duty)
Frequency0.01~120 Hz
Voltage200~230V 3)
Input
ratings
Voltage3Ø200~230V (-15%~+10%)
Frequency50/60 Hz (± 5%)
Protection degreeIP20 / UL Type1IP00 / UL Open 4)
Weight [kg (lbs.)]4.1
(9.0)
4.2
(9.3)
4.2
(9.3)
4.9
(10.8)
4.9
(10.8)
6
(13.2)
6
(13.2)
13
(28.7)
13.5
(29.8)
20
(44.1)
20
(44,1)
3-phase 400V Class (0.75~90kW)
Model Number (SVㅁㅁㅁiP5A-4)008015022037055075110150185220300370450550750900
Capacity [kVA] 1)2.03.24.86.49.612.719.123.931.135.948.659.872.587.6121.1145.8
Output
ratings
Fan or
pump load
Motor rating 2)(HP)12357.5101520253040506075100125
(kW)0.751.52.23.75.57.5111518.522303745557590
Current [A]2.5468121624303945617591110152183
(110% over current)110% 1 Minute (Normal Duty)
General
load
Motor rating(HP)0.512357.5101520253040506075100
(kW)0.40.751.52.23.75.57.5111518.5223037455575
Current [A]1.252.5468.8121622/2428/3034/3944/45
(150% over current)150% 1 Minute (Heavy Duty)
Frequency0.01~120 Hz
Voltage380~480V 3)
Input
ratings
Voltage3Ø380~480V (-15%~+10%)
Frequency50/60 Hz (± 5%)
Protection degreeIP20 / UL Type1IP00 / UL Open 4)
Weight [kg (lbs.)]Standard Type4.1
(9.0)
4.2
(9.3)
4.2
(9.3)
4.9
(10.8)
4.9
(10.8)
6
(13.2)
6
(13.2)
12.5
(27.6)
13
(28.7)
20
(44.1)
20
(44.1)
27
(59.5)
27
(59.5)
29
(64)
43
(94.8)
42
(92.6)
Built-in DCL Type19.5
(43.9)
19.5
(42.9)
26.5
(58.3)
26.5
(58.3)
39
(86)
40
(88.2)
42
(92.6)
67
(147.4)
68
(149.9)
3-phase 400V Class (110~450kW)
Model Number (SVㅁㅁㅁiP5A-2)11001320160022002800315037504500
Capacity [kVA] 1)178210259344436488582699
Output
ratings
Fan or
pump load
Motor rating 2)(HP)150200250350400500600700
(kW)110132160220280315375450
Current [A]223264325432547613731877
(110% over current)110% 1 Minute (Normal Duty)
General
load
Motor rating(HP)125150200250350400500600
(kW)90110132160220280315375
Current [A]183223264325432547613731
(150% over current)150% 1 Minute (Heavy Duty)
Frequency0.01~120 Hz
Voltage380~480V 3)
Input
ratings
Voltage3Ø380~480V (-15%~+10%)
Frequency50/60 Hz (± 5%)
Protection degreeIP00 / UL Open 4)
DCLBuilt-inExternal Option
Weight [kg (lbs.)]101 (222.7)101 (222.7)114 (251.3)200 (441.9)200 (441.9)243 (535.7)380 (837.7)380 (837.7)
3-phase 600V Class (5.5~110kW)
Model Number (SVㅁㅁㅁiP5A-2)0550751101501852203003704505507509001100
Capacity [kVA] 1)9.612.719.123.931.135.948.659.872.587.6121.1145.8178
Output
ratings
Fan or
pump load
Motor rating 2)(HP)7.5101520253040506075100125150
(kW)5.57.5111518.522303745557590110
Current [A]9121723273443556480104128150
(110% over current)110% 1Minute (Normal Duty)
General
load
Motor rating(HP)5.57.5101520253040506075100125
(kW)3.75.57.5111518.522303745557590
Current [A]6.19121723273443556480104128
(150% over current)150% 1 Minute (Heavy Duty)
Frequency0.01~120 Hz
Voltage525 ~600V 3)
Input
ratings
Voltage3f 525~600V (-15% ~ +10 %)
Frequency50/60 Hz (±5 %)
Protection degreeIP20 / UL Type1IP00 / UL Open 4)
Weight [kg (lbs.)]6.5
(14.4)
7.0
(15.5)
7.0
(15.5)
11.7
(25.8)
11.7
(25.8)
18.9
(41.7)
18.9
(41.7)
32
(70.65)
32
(70.65)
32
(70.65)
46
(101.5)
46
(101.5)
101
(223)

1) Rated capacity (v 3 X V X I) is based on 220V for 200V class and 460V for 400V class.
2) Indicates the maximum applicable capacity when using a 4-Pole LS motor.
3) Maximum output voltage will not exceed the input voltage. An output voltage less than the input voltage may be programmed if necessary.
4) IP20/UL Type1 with optional conduit, it can be modified to UL Type-1.