LS-Electric iV5 Drive

LS-Electric iV5 Drive – Find comprehensive resources for LS-Electric iV5 AC drives, including product catalogs, manuals, price list, programming guides, fault, alarm, warnings & software support. Get expert assistance for troubleshooting and optimization.

LS-Electric iV5 Drive image

The LS-Electric iV5 Drive is a series of high-performance vector control inverters designed for demanding industrial applications. User-friendly interface for easy operation and maintenance.

CatalogManual
  • Optimized Solution for System Drive :Control the crane, elevator, and continuous line system based on powerful performance.
  • User-friendly Interface :user-friendly keypads, various field bus options, and DriveView management.
  • High Performance Control system : Speed/Torque control, SIN/COS encoder, PM sensorless, auto tuning, endat encoder, draw/droop/process PID controls, built-in brake control.
  • Various Option for System Application :Synchronize, SIN/COS encoder (Endat encoder), Extension I/O, EL I/O option.

Specification

200V Class

Type : SV[ ][ ][ ]iV5-2(DB)022037055075110150185220300370
Maximum applicable[HP]357.510152025304050
motor ranges 1)[kW]2.23.75.57.5111518.5223037
Rated OutputCapacity[kVA] 2)4.56.19.112.217.522.528.233.14655
Rated Current [A]1216243246597488122146
Output speed0 ~ 3600 (rpm)
Output voltage0 ~ 200V(230V) 3)
Rated inputVoltage3Ø 200 ~ 230V (-10% ~ +10%)
Frequency50 ~ 60Hz (±5%)
Weight[Kg(Ibs)]6(13)6(13)7.7(16.9)7.7(16.9)13.7(30.2)13.7(30.2)20.3(44.7)20.3(44.7)42(93)42(93)

400V Class (AC Power Input Type)

Type : SV[ ][ ][ ]iV5-4(DB)022037055075110150185220300370
Maximum applicable[HP]357.510152025304050
motor ranges[kW]2.23.75.57.5111518.5223037
Rated outputCapacity[kVA]4.56.19.112.218.322.929.734.34657
Rated Current [A]681216243039456175
Output speed0 ~ 3600 (rpm)
Output voltage0 ~ 380V(480V) 3)
Rated inputVoltage3Ø 380 ~ 480V (-10% ~ +10%) 4)
Frequency50 ~ 60Hz (±5%)
Weight[Kg(Ibs)]6(13)6(13)7.7(16.9)7.7(16.9)13.7(30.2)13.7(30.2)20.3(44.7)20.3(44.7)42(93)42(93)
Type : SV[ ][ ][ ]iV5-4(DB)450550750900110013201600220028003150375050008000
Maximum applicable[HP]60751001201501752153003734205006001067
motor ranges[kW]45557590110132160220280315375500800
Rated outputCapacity[kVA]70851161401702002503294164685577321105
Rated Current [A]911101521832232643254325466147319601384
Output speed0 ~ 3600 (rpm)
Output voltage0 ~ 380V(460V) 3)
Rated inputVoltage3Ø 380 ~ 480V (-10% ~ +10%) 4)
Frequency50 ~ 60Hz (±5%)
Weight[Kg(Ibs)]63
(139)
63
(139)
68
(150)
98
(216)
98
(216)
122
(269)
122
(269)
175
(386)
243
(536)
380
(838)
380
(838)
476
(1050)
589
(1300)

400V Class (DC Power Input Type)

SV [ ] [ ] [ ] iV5-4DC055075110150185220300370450550
Maximum applicable[HP]7.5101520253040506075
motor ranges 1)[kW]5.57.5111518.52230374555
outputCapacity[kVA] 2)9.112.218.322.929.734.346577085
Rated Current [A]121624303945617591110
Speed0 ~ 3600 (rpm)
Voltage0 ~ 380V(480V) 3)
Input Rated VoltageDC 540 ~ 680V(+10% ) 5)
Drive weight [Kg(Ibs)]12(26)12(26)24(53)24.5(54)25(55)25(55)38.5(84)38.5(84)50(110)50(110)
SV [ ] [ ] [ ] iV5-4DC75090011001320160022002800315037505000
Maximum applicable[HP]100120150175215300373420500666
motor ranges 1)[kW]7590110132160220280315375500
outputCapacity[kVA] 2)116140170200250329416468557732
Rated Current [A]152183223264325432546614731960
Speed0 ~ 3600 (rpm)
Voltage0 ~ 380V(480V) 3)
Input rated VoltageDC 540 ~ 680V(+10% ) 5)
Drive weight [Kg(Ibs)]55
(121)
79
(174)
79
(174)
98.5
(217)
98.5
(217)
154.5
(340)
206
(454)
343
(756)
343
(756)
466
(1028)

400V Class (MRL)

SV [ ] [ ] [ ] iV5-4(MRL)075110150220
Maximum applicable[HP]10152030
motor ranges[kW]7.5111522
Rated outputCapacity[kVA] 2)13.720.627.539.6
Rated Current [A]18273652
Output speed0 ~ 200 (rpm)
Output voltage380V~480V 3)
Rated inputVoltage3Ø 380 ~ 480V (-10% ~ +10%)
Frequency50~60Hz (±5%)
Weight[Kg(Ibs)]14(30.8)14(30.8)18.7(41)19(41.8)

1) It represents the output capacity 05 maximum applicable motor in case LG-OTIS 4-pole motor is used.

2) Rated capacity (= 3VI) is calculated based on 220V for 200V class, 440V for 400V class.

3) Maximum output voltage cannot be generated greater than the specified input voltage.

4) The rated current is derated by 10% when the input voltage is in the range above 480V.

5) The rated current is derated by 10 % above the 680 VDC of input voltage.