LS-Electric M100 Drive

LS-Electric M100 Drive – Find comprehensive resources for LS-Electric M100 AC drives, including product catalogs, manuals, price list, programming guides, fault, alarm, warnings & software support. Get expert assistance for troubleshooting and optimization.

LS-Electric M100 Drive image

The M100 series is a popular choice for general industrial applications due to its versatility, reliability, and user-friendly design. It is particularly well-suited for applications where space is limited.

The LS-Electric M100 Drive is a compact and versatile variable frequency drive (VFD) designed for a wide range of industrial applications.

CatalogManual
  • Built-in EMC Filter (C2 Class)
  • Built-in DB Unit 1.5kW
  • Quick menu gives easy access to the most frequently used parameters
  • DIN-Rail Mountable
  • Side-by-Side Installation (2mm between drives)
  • Built-in Potentiometer
  • Easy to connect the peripherals
  • Easy to connect the peripherals
  • Smart Copier Connection with RJ45
  • PC Connection with Drive View7 SW control and monitoring system
LSLV M100-EOFN000200040008000100020004000800150022
Applied motorHeavy dutyHP0.250.51.00.1250.250.51.02.03.0
kW0.20.40.750.10.20.40.751.52.2
Rated outputRated capacity [kVA]0.60.951.90.30.60.951.93.04.5
Rated current [A]1.42.44.20.81.42.44.27.510.0
Rrequency [Hz]0~400Hz0~400Hz
Voltage [V]3 phase 200-240V3 phase 200-240V
Rated inputVoltage [V]1 phase 100~120Vac(-15% to +10%)1 phase 200~240Vac(-15% to +10%)
Frequency [Hz]50~60Hz(±5%)50~60Hz(±5%)
Rated current [A]3.77.413.91.01.83.77.113.618.7
Cooling typeNatural coolingNatural coolingForced fan cooling
Weight (Kg)11.360.6611.45

Environment

Environment
Ambient temperature 1)-10 ~ 50℃(14 ~ 122℉), Ambient temperature under the condition of no ice or frost
Ambient humidityRelative humidity less than 95% RH(to avoid condensation forming)
Storage temperature-20 ~ 65℃(-4 ~ 149℉)
Surrounding environemtPrevent contact with corrosive gases, inflammable gases, oil stainsk dust, and other pollutants(Pollution Degree 2 Environment)
Altitude/OscillationMaximum 1000m above sea level for standard operation. / 9.8m/sec2 (1G)
(From 1000 to 4000m, the rated input voltage and rated output current of the drive must be derated by 1% for every 100m.)
Pressure70 ~ 106 kPa

*1) 01 ~ 0.2kW products can be operated at a maximum of 50℃.
However, the lifespan of the product maybe reduced when oprrating continuously with a full load when the ambient temperature exceeds 40℃