Nidec Control Techniques Unidrive M600 Drive

Nidec Control Techniques Unidrive M600 Drive – Find comprehensive resources for Nidec & Control Technique Unidrive M600 AC drives, including product catalogs, manuals, price list, programming guides, fault, alarm, warnings & software support. Get expert assistance for troubleshooting and optimization.

Nidec Control Techniques Unidrive M600 Drive image

Nidec Control Techniques Unidrive M600 is a high-performance AC drive designed for demanding industrial applications that require precise control and advanced functionality. It’s part of the Unidrive M family, known for its flexibility and advanced capabilities.

Power rating:

  • 0.75 kW – 2.8 MW (1.0 – 4,200 hp)
  • 200 V / 400 V / 575 V / 690 V
CatalogManual

Enhanced throughput with high-performance open-loop control of induction and permanent magnet motors

  • Advanced Rotor Flux Control (RFC) algorithm gives maximum stability and control of induction and permanent magnet motors
  • 200% motor overload suitable for heavy industrial machinery applications

Reduce system costs by directly integrating with applications

  • M600 incorporates an onboard PLC which can execute Machine Control Studio (IEC61131-3) programs for logic control, sequencing, speed following and digital lock – removing the need for additional PLCs
  • Fit up to three SI modules to add safe motion, speed feedback, additional I/O and fieldbus communications
  • Open loop vector or V/Hz induction motor control: Open loop motor control for induction motors. Easiest configuration. V/Hz can be used for multiple motor control.
  • Open loop Rotor Flux Control for induction motors (RFC-A) : Vector algorithm utilizing closed loop current control to greatly enhance performance for all induction motor sizes.
  • Open loop permanent magnet motor control (RFC-S) : Open loop control of compact, high efficiency, permanent magnet motors (including the Leroy-Somer Dyneo® LSRPM).
  • Closed loop Rotor Flux Control for induction motors (RFC-A) : Speed and position control for induction motors, supporting a wide range of feedback devices (including quadrature, SinCos, EnDat 2.2, SSI encoders and resolvers).
  • Active Front End (AFE) for power quality and regeneration : Active Front End allows regeneration of energy back onto the power line. The Active Front End also provides power factor control for power quality management and greatly reduces unwanted power harmonics.

Key data

  • Heavy Duty rating: 0.75 kW – 2.8 MW (1.0 – 4,200 hp)
  • Supply phases: 3 phase

Standard features

Intelligence:

  • Onboard PLC
  • Digital Lock Control

Onboard comms:

  • RS485

Machine safety:

  • 1 x Safe Torque Off (STO) terminal
  • SIL3/PLe compliant

Keypad:

  • No keypad as standard

Option slots:

  • 3

Parameter cloning via:

  • PC tools
  • Smartcard
  • SD card

Voltage ratings

200 V (200 V – 240 V ± 10%)
400 V (380 V – 480 V ± 10%)
575 V (500 V – 575 V ± 10%)
575 V (500 V – 575 V ± 10%)
690 V (500 V – 690 V ± 10%)

Control mode

Open loop vector or V/Hz induction motor control
Open loop Rotor Flux Control for induction motors (RFC-A)
Open loop permanent magnet motor control (RFC-S)
Open loop permanent magnet motor control (RFC-S)
Closed loop Rotor Flux Control for induction motors (RFC-A) *Optional
Active Front End (AFE) power quality convertor

Single drives

FRAME
SIZE
DIMENSIONS
(H X W X D)
WEIGHT
 mminkglb
3382 x 83 x 20015.0 x 3.3 x 7.94.5 Max9.9 Max
4391 x 124 x 20015.4 x 4.9 x 7.96.514.3
5391 x 143 x 20015.4 x 5.6 x 7.67.416.3
6391 x 210 x 22715.4 x 8.3 x 8.91430.9
7557 x 270 x 28021.9 x 10.6 x 11.02861.7
8803 x 310 x 29031.6 x 12.2 x 11.452114.6
9A1108 x 310 x 29043.6 x 12.2 x 11.466.5146.6
9E1069 x 310 x 28842.1 x 12.2 x 11.346101.4
10E1069 x 310 x 28842.1 x 12.2 x 11.346101.4
11E1410 x 310 x 31055.5 x 12.2 x 12.263138.9
121750 x 295 x 526
68.9 x 11.6 x 20.7
AC to AC (‘T’ type): 130
DC to AC (‘D’ type): 113
287
249

All dimensions include mounting brackets

Modular drives

FRAME SIZEDIMENSIONS (H X W X D)
 mmin
INVERTER & RECTIFIER
9A1108 x 310 x 29043.62 x 12.21 x 11.4
9E | 9T1069 x 310 x 29042.1 x 12.21 x 11.4
10E | 10T1069 x 310 x 29042.1 x 12.21 x 11.4
11E | 11T1242 x 310 x 31248.9 x 12.2 x 12.3
INVERTER
9D773 x 310 x 29030.4 x 12.2 x 11.4
10D773 x 310 x 29030.4 x 12.2 x 11.4
11D863 x 310 x 29034 x 12.2 x 12.3
RECTIFIER
10A6 pulse 355 x 310 x 2906 pulse 13.9 x 12.2 x 11.4
11A | 11T6 pulse
415x 310 x 290
12 pulse
415x 310 x 290
6 pulse
16.3 x 12.2 x 11.4
12 pulse
16.3 x 12.2 x 11.4

All dimensions include mounting brackets

Power and current ratings 

The continuous current ratings given are for maximum 40 °C (104 °F), 1000 m altitude and 2 kHz switching frequency. Derating is required for higher switching frequencies, ambient temperature >40 °C (104 °F) and high altitude.

200 V (200 V to 240 V ±10%)

Product Code
M600/M700/M701
/M702
 Normal Duty
Heavy Duty 
Supply Phases Max Cont. Current
(A)

Motor Power
(kW)

Motor Power
(HP)
 
Max Cont. Current
(A)

Motor Power
(kW)

Motor Power
(HP)

Mxxx – 03200050A 36.6  1.1 1.550.751
Mxxx – 03200066A3 8 1.5 26.61.11.5
Mxxx – 03200080A3 11 2.2 381.5
Mxxx – 03200106A 12.7 3 310.62.2 3
Mxxx – 04200137A 18 4 513.73
Mxxx – 04200185A 24 5.5 7.518.54
Mxxx – 05200250A 30 7.5 10255.57.5 
Mxxx – 06200330A 50 11 1533 7.510 
Mxxx – 06200440A 58 15 2044 1115 
Mxxx – 07200610A 75 18.5 2561 1520 
Mxxx – 07200750A 94 22 3075 18.525 
Mxxx – 07200830A 117 30 40832230 
Mxxx – 08201160A 149 37 50116 3040 
Mxxx – 08201320A 180 45 60132 3750 
Mxxx – 09201760A 216 55 75176 4560 
Mxxx – 09202190A3 266 75 100219 5575 
Mxxx – 09201760E 216 55 75176 4560 
Mxxx – 09202190E 266 75 100219 5575 
Mxxx – 10202830E 325 90 125283 75100 
Mxxx – 10203000E3 360 110 15030090125 

400 V (380 V to 480 V +/-10%)

Product Code
M600/M700/M701/M702
 Normal DutyHeavy Duty
Supply Phases Max Cont. Current
(A)
 Motor Power
(kW)
 Motor Power
(HP)
Max Cont. Current
(A)

Motor Power
(kW)

Motor Power
(HP)

Mxxx – 03400025A
33.41.11.52.50.751
Mxxx – 03400031A
34.51.523.11.11.5
Mxxx – 03400045A
36.22.234.51,52
Mxxx – 03400062A
37.7356.22.23
Mxxx – 03400078A
310.4457.835
Mxxx – 03400100A
312.35.57.51045
Mxxx – 04400150A
318.57.510155.510
Mxxx – 04400172A
324111517.27.510
Mxxx – 05400270A
3301520271120
Mxxx – 05400300A
3311520301520
Mxxx – 06400350A
33818.525351525
Mxxx – 06400420A
34822304218.530
Mxxx – 06400470A
3633040472230
Mxxx – 07400660A
3793750663050
Mxxx – 07400770A
3944560773760
Mxxx – 07401000A
311255751004575 
Mxxx – 08401340A
31557510013455100
Mxxx – 08401570A
31849012515775125
Mxxx – 09402000A
322111015020090150
Mxxx – 09402240A
3266132200224110150
Mxxx – 09402000E 
322111015020090150 
Mxxx – 09402240E
3266132200224110150 
Mxxx – 10402700E
3320160250270132200 
Mxxx – 10403200E
3361200300320160250 
Mxxx – 11403770E
3437225350377185300 
Mxxx – 11404170E
3487250400417200350 
Mxxx – 11404640E
3507280450464250400 
Mxxx -12404800
3608315500480250400
Mxxx -12405660
3660355550566315450 
Mxxx -12406600
37554006506602355550 
Mxxx -12407200
38651
5007007203400600

Note1 110 % Overload at 30˚C and below and No Overload above that.
Note2 140 % Overload at 35˚C and below and 125% above that.
Note3 140 % Overload at 30˚C and below and 125% above that.

575 V (500 V to 575 V +/-10%)

Product Code
M600/M700/M701/M702
 Normal DutyHeavy Duty
Supply Phases Max Cont. Current
(A)
Motor Power
(kW)

Motor Power
(HP)

Max Cont. Current
(A)

Motor Power
(kW)

Motor Power
(HP)

Mxxx – 05500030A 
33.92.2331.52
Mxxx – 05500040A
36.14542.23
Mxxx – 05500069A 
3105.57.56.945
Mxxx – 06500100A 
3127.510105.57.5
Mxxx – 06500150A 
3171115157.510
Mxxx – 06500190A 
3221520191115
Mxxx – 06500230A 
32718.525231520
Mxxx – 06500290A 
33422302918.525
Mxxx – 06500350A 
3433040352230
Mxxx – 07500440A 
3534550443040
Mxxx – 07500550A 
3735560553750
Mxxx – 08500630A 
3867575634560
Mxxx – 08500860A
310890100865575
Mxxx – 09501040A
312511012510477100
Mxxx – 09501310A
315011015013190125
Mxxx – 09501040E
312511012510475100
Mxxx – 09501310E 
315011015013190125
Mxxx – 10501520E 
3200130200152110150
Mxxx – 10501900E
3200150200190132200
Mxxx – 11502000E
3248185250200150200
Mxxx – 11502540E
3288225300254185250
Mxxx – 11502850E
315250350285225300
Mxxx-12503150
3376250350315
250
350
Mxxx-12503600
3428300400360250350
Mxxx-12504100
3480330450410
300
400
Mxxx-12504600
3532370500460330
450

690 V (500 V to 690 V +/-10%

Product Code
M600/M700/M701/M702
Normal Duty Heavy Duty
Supply PhasesMax Cont. Current
(A)
Motor Power
(kW) 
Motor Power
(HP) 
Max Cont. Current
(A)
Motor Power
(kW)
Motor Power
(HP)
Mxxx – 07600190A
32318.525191520
Mxxx – 07600240A
33022302418.525
Mxxx – 07600290A
3363040292230
Mxxx – 07600380A 
3463750383040
Mxxx – 07600440A
3524560443750
Mxxx – 07600540A
3735575544560
Mxxx – 08600630A
38675100635575
Mxxx – 08600860A
3108901258675100
Mxxx – 09601040A
312511015010490125
Mxxx – 09601310A
3150132175131110150
Mxxx – 09601040E
312511015010490125
Mxxx – 09601310E
3155132175131110150
Mxxx – 10601500E
3172160200150132175
Mxxx – 10601780E
3197185250178160200
Mxxx – 11602100E
3225200250210185250
Mxxx – 11602380E
3275250300238200250
Mxxx-12603150
3376355450 315280400
Mxxx-12603600
3428400500 360355450
Mxxx-12604100
3480450600 410400
500
Mxxx-12604600
3532500650 460450600