Toshiba AS1 Drive is a heavy-duty, general-purpose adjustable speed drive (ASD) designed for a wide range of industrial applications. It’s designed to handle tough applications and withstand challenging operating conditions.
Features
The AS1’s advanced features and new technologies make it the new contender in the PWM control drive market. The modular construction of the AS1 allows the unit to be installed into nearly any application quickly and easily. The drive can operate with little or no programming. At the same time, the AS1 maintains one of the most expansive parameter sets in the industry. Its sealed cabinet design, new PID algorithm and motor-over-flux-braking technology make this drive adept to handle the most difficult applications.
- Advanced Design: The modular construction of the AS1 allows the unit to be installed into nearly any application quickly and easily.
- Simple Programming: Toshiba’s unified programming philosophy means that you can operate the AS1 drive with little or no programming.
- Tough Environment: The AS1 drive is designed to operate in extreme environments. It can operate in temperatures up to 122°F without derating and can also be configured for use in temperatures of up to 140°F
- Improved Control: The AS1’s new PID algorithm makes it easier than ever to dial in your process control application
- Powerful Performance: The AS1 offers both sensorless and feedback vector control providing heavy duty performance.
- Smart Operation: Toshiba’s “My Function” programming set allows the AS1 to operate as a simple PLC.
- Fault-Tracing: Issues with your application will no longer be a mystery with AS1’s fault-tracing algorithm
- Easy Communications: The AS1 is designed to accommodate multiple stackable option cards that mount underneath the unit’s keypad quickly and easily.
Specifications:
Standard Specifcations | ||||
Model Range | 0.5 to 100 HP | 1 to 800 HP | 2 to 10 HP | 2 to 700 HP |
Voltage Rating | 200 to 240 V | 380 to 460 V | 500 to 600 V | 500 to 690 V |
Input Tolerance | Voltage: ±10%, Frequency: ±5% | |||
Current Overload | 100% Continuous, 150% for 60 Seconds, 165% for 2 Seconds | |||
DC Reactor | 200 V Input Class, 15 to 60 HP and 400 V Input Class, 25 to 100 HP: Built-In DC Link Reactor; Reactors Required on Larger Units, Optional on Smaller Units (HP) | |||
Dynamic Braking | Dynamic Braking Resistor Included on Units < 300 HP; Transistor for Larger Units/Resistor Sold Seperately | |||
Control System | Sinusoidal Pulse Width Modulation (PWM) Control | |||
Output Frequency Range | 0 to 500 Hz | |||
Frequency Accuracy | Analog Input: ±0.2% of Maximum Output Frequency (at 25 ±10°C); Digital Input: ±0.01% (±0.022 Hz) of Output Frequency | |||
Voltage/Frequency Characteristics | Constant Torque, Square Reduction Torque, Auto-Torque Boost, Sensorless and PG Feedback Vector Control, etc. | |||
Jump frequencies | Voltage: ±10%, Frequency: ±5% | |||
PID Control | Adjustment of Proportional Gain, Integral Time, Differential Time, and Delay Filter | |||
Torque Control | Control of Output Motor Torque via Set Point from 0 to 10 V Analog Input | |||
PWM Carrier Frequency Adjustment | 200 V, 45 kW or 400 V, 75 kW or less, Adjustable Between 1.0 to 16 kHz; 200 V, 55 kW or 400 V, 90 kW or more, Adjustable Between 2.5 to 8 kHz | |||
Analog Inputs | 0 to 10 Vdc (Input Impedance Zin: 30 kΩ), 0 to ±10 Vdc (Zin: 22 kΩ), 4 to 20 mAdc (Zin: 242 Ω) | |||
Analog Outputs | FM Terminal: 0 to 1 mA, 0 to 20 mA, 0 to 10 V: AM Terminal: 0 to 1 mA, Each Programmable to Any of 65 Functions | |||
Digital Inputs | Up to 8 Digital Inputs, Each Programmable to 67 Functions, Normally Open or Normally Closed | |||
Digital Outputs | One Form-C Relay (FM) Output (250 Vac, 2 A or 30 Vdc,1 A); Two Open Collector Outputs (24 Vdc, 5 mA) | |||
Acceleration/Deceleration Time | 0.01 to 6000 Seconds; Four Selectable or Automatic Acceleration/Deceleration Times; Two Adjustable S-Pattern Acceleration/Decelerations | |||
DC Braking | Adjustment of DC Braking Start Frequency (0 to 120 Hz), Braking (0 to 100%), and Braking Time (0 to 20 Seconds); Includes Emergency Stop Braking and Motor Shaft Fix Control Functions | |||
Forward Run/Reverse Run | F-CC Closed will Forward Run, R-CC Closed will Reverse Run, F-CC and R-CC Closed will Reverse Run; ST-CC Opened will Coast Stop; Emergency Stop Using Panel Operation or Terminal Board | |||
Jog Run | Jog Mode Allows Jog Operation from Operation Panel; Jog Run Operation by Terminal Board Possible by Setting Parameters | |||
Preset Speed Operation | 15 Preset Speeds Available by Switch Input; Programmable Accel/Decel Time; Torque Limit and V/F | |||
Retry | Capable of Restarting After Checking Main Circuit Elements in the Event of a Fault; Up to 10 Retries with Adjustable Delay (of up to 10 Seconds) Between Each Retry | |||
Soft Stall | Automatic Load Reduction Control in the Event of Overload Condition (Default: OFF) | |||
Cooling Fan ON/OFF | Cooling Fan Stops Automatically When Not Needed | |||
Operation Panel Key Operation On/Off Control | Keypad Lockout Selectable Between STOP Key Only, MODE Key Only, etc.; All Key Operations can be Prohibited | |||
Regen Power Ride Through | In case of a momentary power failure, the VFD can use regen energy to stay powered. (Default: OFF) | |||
Auto-Restart Operation | AS1 can catch a spinning motor and safely bring it to speed without faulting. (Default: OFF) | |||
Simplified Pattern Operation | Selectabe: Eight Patterns in Two Groups from 15 Speed Operations; Maximum 16 Types of Operations Possible; Terminal Board Operation/Repeat Operation Possible | |||
Commercial Inverter Switching | Possible to Switch Operation Using Commercial Power Source or Inverter | |||
Light Load, High-Speed Operation | Increases Efficiency of Certain Machines by Increasing Rotational Speed of Motor when Operated with Light Load | |||
Drooping Function | When Two or More Inverters Operate a Single Load, Drooping Function Helps Evenly Share Load | |||
Override Function | Allows User to Add to the Primary Frequency Command. (E.G. Trim input) | |||
My Function Operation | My Function provides digital logic and comparator operations as well as timers, counters, and other control functions to provide advanced control operations directly on the VFD (similar to a micro PLC). | |||
Color | RAL7016 (Charcoal Gray) | |||
Environment | Indoor Use, Non-Corrosive/Non-Combustible Environment; Altitude: 3000 Meters or Less (Derating Necessary for Elevations Over 1000 Meters); Keep Out of Direct Sunlight | |||
Ambient Temperature | -10 to +60°C; Remove Upper Cover if 40°C or Higher, Maximim 60°C with De-Rate) | |||
Storage Temperature | -25 to +70°C | |||
Relative Humidity | 20 to 93% (Free from Condensation) | |||
Vibration | 5.9 m/s2{0.6 G} or Less (10 to 55 Hz) |
Applications:
The Toshiba AS1 Drive is used in various industrial sectors, including:
- Manufacturing
- HVAC
- Pumping
- And other general-purpose industrial applications.