Toshiba H7 Drive

Toshiba H7 Drive – Find comprehensive resources for Toshiba H7 AC drives, including product catalogs, manuals, price list, programming guides, fault, alarm, warnings & software support. Get expert assistance for troubleshooting and optimization.

Toshiba H7 Drive image

Toshiba H7 Drive is a robust and versatile adjustable speed drive designed for demanding industrial applications. It’s built to handle heavy loads and provide precise motor control.

CatalogManual

The H7 adjustable speed drive is ready for continuous, trouble-free operation in demanding manufacturing environments. It features open- or closed-loop true torque control, which is Toshiba’s vector algorithm that enables motors to develop high starting torque compensation for motor slip. A graphics-capable, back-lit LCD display, RS485/RS232 ports, and a programming/speed control encoder round off this advanced drive.

  • Industrial Focus: The H7 is engineered for continuous, reliable operation in harsh manufacturing environments.
  • Advanced Control Technology: It features Toshiba’s “TRUE TORQUE CONTROL2” algorithm, which enhances torque control in both sensorless and feedback vector control modes.
  • Dynamic Mode Switching: The H7’s dynamic mode switching allows you to change between speed and torque control or position control modes on-the-fly for seamless operation.
  • Built-In Communications : Toshiba’s H7 comes standard with RS232/485 and TTL communications ports.
  • Adaptability: The H7’s programmable discrete inputs may be configured to any of 68 different functions and are independently selectable for normally open or normally closed operation.

Applications: The H7 is suitable for a broad range of industrial applications requiring precise motor control and reliability. The H7 is suitable for a variety of applications that require unparalleled motor control, rugged reliability, and a user-friendly operator interface.

Specifications

H7 ASD Standard Specifications
Model Range3 to 150 HP5 to 400 HP3 to 15 HP20 to 350 HP
Voltage Rating200 to 240 V380 to 480 V520 to 600 V520 to 600 V
Input Voltage Tolerance±10%±10%+5% / -10%±10%
Voltage RegulationMain Circuit Voltage Feedback Control (Automatic Regulation, ‘Fixed’ and ‘Control Off’ Selections)
PWM Carrier FrequencyAdjustable between 0.5 through 15 kHz (ASD Specific, Consult Factory)
Control SystemSine Wave PWM System; Flux Field Current Vector Control
V/f PatternOpen Loop Vector, Closed Loop Vector, Constant Torque, Variable Torque, Auto-Torque Boost, Manual Torque Boost, 5-Point V/f Custom Curve Setting
Overload Current Rating100% Continuous or 120% for One Minute
Frequency SettingRotary Encoder Integrated into the EOI, 0 to 10 V, ±10 V, 4 to 20 mA, Binary Input, Motorized Potentiometer Input
Frequency PrecisionAnalog Input ±0.2% of the Maximum Output Frequency, Digital Input ±0.01% of the Maximum Output Frequency
Frequency Command Resolution0.01 Hz Operation Panel, 0.1 Hz Analog Input; 10 to 12-Bit A to D Converter
Output Frequency Range0 to 299 Hz
Speed RegulationClosed Loop (0.01%, 1000:1 Speed Range), Open Loop (up to 0.1%, 60:1 Speed Range)
Torque RegulationClosed Loop (5%, Ripple < 2%, ±100% Range), Open Loop (10%, Ripple < 3%, 50% To 100% Range)
Discrete Input TerminalsEight Discrete Input Terminals Programmable To 68 Functions; Number of Terminals may be Increased Using Optional Hardware.
Analog InputsOne 4 to 20 mA, One ±10 V, and Two 0 to 10 V (One of which is Commonly Used with a Potentiometer)
Discrete Output ContactsThree Discrete Output Contacts Programmable to 60 Functions
Analog OutputsTwo 4 to 20 mA; 0 to 1 mA Outputs Programmable to 33 Functions
Signal IsolationOptional Three-Channel Signal Isolation for 4 to 20 mA inpu; AM and FM Outputs Rated at 750 V
Control Board Communications PortsRS232/485 and TTL Ports Standard
Power TerminalsInput (L1, L2, L3), Output (T1, T2, T3), DCL (PO, PA), DBR (PA, PB), DC BUS (PA, PC)
Set Point Control (PID)Proportional Gain, Integral Gain, Feedback Settings Upper / Lower Deviation Limits, Feedback Source Delay Filter, Feedback Settings Differential Gain
Control PowerDC Bus Control; Power Allows Control Power Ride-through During Momentary Power Loss (Except 600 V 100 HP and Larger)
  Protective FunctionsFault Input And Outputs Fail-safe Configured. Fault Codes Include: Overcurrent, Overvoltage, Heatsink Overheat, Load-Side Short Circuit, Load Side Ground Fault, ASD Overload, Overcurrent During Start-Up, EEPROM Error, RAM Error, ROM Error, Communications Error, Armature Short, Auto-Tuning Error, Dynamic Braking Overcurrent, Dynamic Braking Resistor Overload, Emergency Stop, Undervoltage, Overtorque, Open Output Phase, Motor Overload, Loss of Feedback
RetryASD can Clear Fault upon Trip Automatically; Programmable to 10 Times with Wait Time up to 10 Seconds Between Retries.
RestartASD will catch a freewheeling motor smoothly.
AmbientTemperature: -10 to + 40° C, 14 to 104° F, Humidity: 95% Non-Condensing
InstallationNEMA 1
Electronic Operator Interface (EOI)
Liquid Crystal Display/ Electronic Operator Interface (LCD EOI)124 x 64 Graphics Capable, Back-Lit LCD can Display Multiple Parameters Simultaneously; Keypad may be Operated from External Power Source; Software is Flash Upgradeable.
LED IndicationsRun (Red)/Stop (Green), Local/Remote (Green), DC Bus Charge Indication (Red)
KeysLocal/Remote, Monitor/Program, Run, Enter, ESC, Stop/Reset, Up, Down
Rotary EncoderEncoder with Integrated Enter Key for Frequency and Parameter Adjustments
  MonitoringMain Display Shows Two Monitored Items or can Display up to 45 User-Selected Scrolling Items Including: Terminal Input/Output Status, Forward/Reverse, Frequency Setting Value, Output Frequency, Output Current, Output Voltage, Input Power, Output Power, Torque Current, Past Faults, Excitation Current, DBR Overload Ratio, ASD Overload Ratio, Motor Overload Ratio, PID Feedback Value, DC Voltage
Selectable Display UnitsCompletely Configurable along with Scaling Factor Multiplier, Current Display Selectable between Amps or %, Voltage Display Selectable between Volts or %
EOI Communications PortsRS232/485 and TTL Ports Standard
Remote-Mount DisplayRemote Mountable up to 1000’ from ASD

Dimension

H7B Dimensions HxWxD (Inches)
230 V3 to 7.5 HP10 to 25 HP30 HP40 to 50 HP60 HP75 to 100 HP125 to 150 HP 
460 V5 to 10 HP15 to 50 HP 60 to 100 HP125 HP150 to 200 HP250 to 350 HP400 HP
600 V3 to 15 HP20 to 60 HP 75 to 100 HP 125 to 200 HP200 to 350 HP 
Height8.4714.2215.7224.6326.4738.6350.0073.00
Width7.2812.1612.1617.5017.5017.5024.1524.00
Depth7.3311.2311.2312.8112.8113.7820.0020.00