Toshiba Q9 Drive

Toshiba Q9 Drive – Find comprehensive resources for Toshiba Q9 AC drive, including product catalogs, manuals, price list, programming guides, fault, alarm, warnings & software support. Get expert assistance for troubleshooting and optimization.

Toshiba Q9 drive image

The Q9 adjustable speed drive is a solid-state AC drive designed for commercial variable torque applications such as fans and pumps for VAV systems, cooling towers, and pump systems.

CatalogManual

The Q9 features a multi-functional LCD display that provides a programming interface, monitoring display, and operation mode. The Q9 provides protection against drive overload, motor overload, overvoltage, and ground faults, to name a few. These features make the Q9 suitable for a wide variety of applications that require reliable motor control.

  • Process control on the HVAC marketed Q9+ allows for reduction or eliminated usage of dampers for HVAC
  • Automated process control can reduce wear and tear on all equipment reducing maintenance and extending the life of the system. By monitoring the motor load and current, the motor lifespan will also drastically be extended when put on an ASD
  • The Q9+ offers the same VLP Technology® as the P9 drive

Specification

Below table shows Toshiba Q9 Drive specifications:

Q9 Standard Specifications
Input Voltage230 V
HP Rating12357.51015202530405060
Current Rating4.87.81117.525.332.248.362.178.292120150177
Input Voltage460 V, 50/60 Hz, Three-Phase
HP Rating12357.51015202530405060
Current Rating2.13.44.87.6111421273440526577
HP Rating75100125150200250300350400 
Current Rating96124156180240302361414477
Power Requirements
Input Voltage Range200 to 240 V, 50/60 Hz, Three-Phase380 to 480 V, 50/60 Hz, Three-Phase
Power TerminalsInput (L1/R, L2/S, L3/T), Output (T1/U, T2/V, T3/W), DCL (PO, PA), DC Bus (PA, PC)
Voltage Tolerance±10%
Frequency Tolerance±2%
Control Specifications
Output MethodSine Wave Pulse-Width Modulated System
Output Frequency Range0 to 299 Hz
V/Hz PatternConstant Torque, Variable Torque, Automatic Torque Boost, Sensor-Less Vector Control (Speed), V/f Five-Point Setting, Permanent Magnet Control, Auto Power-Saver
Overload Current Rating100% Continuous; 110% for One Minute
Frequency ControlRotary Encoder Integrated Into EOI, 0 to 10 VDC, ±10 VDC, 4 to 20 mA, Binary Input, Motor Operated Potentiometer
Frequency AccuracyAnalog Input: ±0.2% of Maximum Output Frequency; Digital Input: ±0.01% of ±0.022 Hz of Output Frequency
Frequency ResolutionOperation Panel: 0.01 Hz
Acceleration/Deceleration0.1 to 6000 Seconds
Analog InputsThree: One Isolated Input Selectable Between 0 to 10 VDC/4 to 20 mA, One 0 to 10 VDC, and One ±10 VDC
Analog OutputsTwo Programmable to 57 Functions (One Switchable 0 to 10 VDC/0 to 20 mA, and One 0 to 1 mA)
Discrete InputsEight Programmable to 41 Functions
Sink/Source SwitchingAbility to Switch Between Sink Logic and Source Logic
Discrete OutputsThree Programmable to 83 Functions (Two Form-A and One Form-C); Outputs Rated at 2 A/120 VAC, 2 A/30 VDC
PID (Set Point Control)Adjustment of Proportional Gain, Integral Time, Differential Time, and Delay Filter
Braking ControlDC Braking, Over-Flux Braking
Communication PortsTwo-Wire/Four-Wire RS485
Communication ProtocolBACNet®, LonWorks®, Metasys N2®, Modbus RTU®, APOGEE FLN®
Protection
Protective FunctionsOvervoltage Stall, Overcurrent Stall, Critical (Skip) Frequencies, Ride-Through, Electronic Thermal Motor Protection
Interrupting Current Rating100,000 AIC
FaultsOvercurrent, ASD Overheat, ASD Overload, Motor Overload, Overvoltage, Overtorque, Undercurrent, Ground Fault, Communication Time-Out, Analog-Input Terminal Overvoltage, Emergency Stop, Input/Output Phase Loss, RAM/ROM Error, Undervoltage
RetryAbility to Reset Certain Faults Automatically; Programmable Up to 10 Retries
RestartAbility to Detect Speed and Direction of Freewheeling Motor and Start into Motor Smoothly
Interface
EOI DisplayFull-English Backlit LCD Display
KeysLOCAL/REMOTE, ESC, RUN, MODE, STOP/RESET
Rotary EncoderEncoder with Integrated Enter Key for Frequency and Parameter Adjustments
MonitoringMonitors 19 Drive Conditions
Display UnitsProgrammed to Display Percentage or Volts/Amps
Ambient Conditions
Temperature-10˚ to 40˚C
Relative HumidityMaximum 93% (Non-Condensing)
Altitude1000 Meters or Less

Dimensions

Below table shows Toshiba Q9 Drive dimensions:

Q9 Dimensions
230 V1 to 2 HP3 to 5 HP7.5 HP10 HP15 to 20 HP25 to 30 HP40 to 60 HP100 HP125 HP
460 V1 to 3 HP5 to 7.5 HP10 HP15 to 20 HP25 to 30 HP40 HP50 to 60 HP75 to 125 HP150 HP200 HP250 HP300 to 350 HP400 HP
Frame2345A5B67A7B89B10B11B12B13A
Height (in.)10.011.112.612.615.716.521.721.724.836.240.246.946.946.9
Width (in.)5.16.16.98.39.19.49.412.612.612.213.813.016.923.0
Depth (in.)6.06.56.57.57.58.38.39.511.414.614.614.614.614.6