A7441 fault in siemens sinamics V90 drive

A7441 alarm in siemens sinamics V90 drive indicates a prompt to Save the position offset of the absolute encoder adjustment. This means a new absolute encoder position has been established but still needs to be permanently saved to memory.

Cause: The status of the absolute encoder adjustment has changed. In order to permanently save the determined position offset (p2525) it must be saved.

Remedy: Not necessary. This alarm automatically disappears after the offset has been saved.