Hitachi NE S1 Drive

Hitachi NE S1 Drive – Find comprehensive resources for Hitachi NE S1 AC drives, including product catalogs, manuals, price list, programming guides, fault, alarm, warnings & software support. Get expert assistance for troubleshooting and optimization.

Hitachi NE S1 Drive image

Hitachi NE-S1 series is designed as an economical and user-friendly variable frequency drive (VFD) for basic applications. Its ultra-compact design allows for space-saving installations, which is beneficial in tight control panels.

CatalogManual

Hitachi NE S1 Drive is built to be a cost-effective solution, especially for those needing basic VFD functionalities.

  • PID control.
  • Logic and time delay functions.
  • RS-485 Modbus RTU communication as a standard feature.
  • Energy saving functions
  • Optional operator displays further enhance usability.

General Specifications

ItemGeneral Specifications
          ControlControl methodLine-to-line sine wave pulse-width modulation (PWM) control
Output frequency range *50.5 to 400Hz
Frequency accuracy *6Digital command :±0.01%, Analog command ±0.2% (25 ±10˚C)
Frequency setting resolutionDigital: 0.1Hz, Analog: (max frequency)/1000
Voltage/Frequency CharacteristicV/f control,V/f variable (constant torque, reduced torque)
Acceleration/deceleration time0.00 to 3000 sec. (linear, sigmoid), two-stage accel./decel.
Starting torque *7100%/6Hz
Carrier frequency range2.0 to 15kHz
Protective functionsOver-current, Over-voltage, Under-voltage, Overload, Overheat, Ground fault at power-on, Input over-voltage, External trip, Memory error, CPU error, USP error, Driver error, Output phase loss protection
        Input terminalSpecification10kohm input impedance, sink/source logic selectable
      FunctionsFW(Forward), RV(Reverse), CF1-CF3(Multispeed command), JG(Jogging), DB(External DC braking), SET(Second motor constants setting), 2CH(Second accel./decel.), FRS(Free-run stop), EXT(External trip), USP(Unattended start protection), SFT(Software lock), AT(Analog input selection), RS(Reset), STA(3-wire start), STP(3-wire stop), F/R(3-wire fwd./rev.), PID(PID On/Off), PIDC(PID reset), UP/DWN(Remote-controlled accel./decel.) , UDC(Remote-controlled data clearing), OPE(Operator control), SF1-SF3(multispeed bit), OLR(overload restriction selection), LAC(LAD cancellation, ADD(ADD frequency enable), F-TM(force terminal mode), KHC(cumulative power clearance), AHD(analog command holding), HLD(retain output frequency), ROK(permission of run command), DISP (display limitation), NO(Not selected)
        Output signal    Intelligent output terminalSpecification27V DC 50mA max open collector output, 1 terminals 1c output 250V AC/30V DC 2.5A relay (AL0, AL1, AL2 terminals)
    FunctionRUN(run signal), FA1(Frequency arrival type 1 – constant speed), FA2(Frequency arrival type 2 – over-frequency), OL(overload advance notice signal), OD(Output deviation for PID control), AL(alarm signal), DC(Wire brake detect on analog input), FBV(PID Second Stage Output), NDC(ModBus Network Detection Signal), LOG(Logic Output Function), ODC(analog voltage input disconnection), LOC(Low load), FA3(Set frequency reached), UV(Under voltage), RNT(Operation time over), ONT(Plug-in time over), THM(Thermal alarm signal), ZS(0 Hz detection signal), IRDY(Inverter ready), FWR(Forward rotation),RVR(Reverse rotation), MJA(Major failure)
Moniter output terminalFunctionPWM output; Select analog output frequency monitor, analog output current monitor or digital output frequency monitor
      Operator    Operation key1 unified key for RUN/STOP/RESET ON : this key has function of “RUN”(regardless run command source setting (A002/A201).) OFF : this key has function of “STOP/RESET When optional operator is connected, operation from key is disabled.
Status LED InterfaceControl power supply LED (Red),LED during operation (yellow-green),Operation button operation LED (yellow-green),LED during tripping (Red), 4LED in total
      OperationFrequency settingOperator keypad(Option)Up and Down keys / Value settings or analog setting via potentiometer on operator keypad
External signal *80 to 10 V DC or 4 to 20 mA
Serial portRS485 interface (Modbus RTU)
  FW/RV RunOperator Keypad(Option)Run key / Stop key (change FW/RV by function command)
External signalFW Run/Stop (NO contact), RV set by terminal assignment (NC/NO), 3-wire input available
Serial portRS485 interface (Modbus RTU)
    EnvironmentOperating temperature-10 to 50˚C(carrier derating required for aambient temperature higher than 40°C), no freezing
Storage temperature-20 to 60˚C
Humidity20 to 90% RH
Vibration5.9mm/s2 (0.6G) 10 to 55Hz
LocationAltitude 1,000 m or less, indoors (no corrosive gasses or dust)
Other functionsAVR (Automatic Voltage Regulation), V/f characteristic selection, accel./decel. curve selection, frequency upper/lower limit, 8 stage multispeed, PID control, frequency jump, external frequency input bias start/end, jogging, trip history etc.
OptionsRemote operator with copy function (WOP), Remote operator (OPE-SRmini, OPE-SR), Operator (NES1-OP), input/output reactors, DC reactors, radio noise filters, LCR filter, communication cables (ICS-1, 3)

Note 1: The applicable motor refers to Hitachi standard 3-phase motor (4-pole). When using other motors, care must be taken to prevent the rated motor current (50/60 Hz) from exceeding the rated output current of the inverter.

Note 2: The output voltage decreases as the main supply voltage decreases (except when using the AVR function). In any case, the output voltage cannot exceed the input power supply voltage.

Note 3: The braking torque via capacitive feedback is the average deceleration torque at the shortest deceleration (stopping from 50/60 Hz as indicated). It is not continuous regenerative braking torque. The average decel torque varies with motor loss. This value decreases when operating beyond 50 Hz.

Note 4: The protection method conforms to JEM 1030.

Note 5: To operate the motor beyond 50/60 Hz, consult the motor manufacturer for the maximum allowable rotation speed.

Note 6: The output frequency may exceed the maximum frequency setting (A004 or A204) for automatic stabilization control.

Note 7: At the rated voltage when using a Hitachi standard 3-phase, 4pole motor. Note 8: DC 4 to 20 mA Input, need parameter setting by Keypad etc. Analog input voltage or current can be switched by switch as individually and not use them in the same time

This series is well-suited for applications where basic speed control is required, such as:

  • Fans
  • Pumps.
  • Conveyors.
  • Light-duty machinery.