Hitachi S1 Drive – Find comprehensive resources for Hitachi S1 AC drives, including product catalogs, manuals, price list, programming guides, fault, alarm, warnings & software support. Get expert assistance for troubleshooting and optimization.
Hitachi S1 series is a line of versatile and user-friendly inverters (variable frequency drives or VFDs) designed for a broad range of industrial applications.
Hitachi S1 drive is perceived as the new standard for general purpose inverter, highly flexible and user friendly for easy commissioning. It is suitable for a wide range of applications, using advanced sensorless vector control. S1 achieves exceptional stability and efficient drive characteristics to save energy and maximize performance.
Supports SVC control
Enables high precision of speed torque control and fast speed response
Automatic voltage regulation (AVR), Torque compensate function
Optional parameter copy LED external keypad, meeting the requirements of diverse applications
General specifications
Function
(0.4kW–2.2kW)
(4.0kW–500kW)
Inputvoltage(V)
AC 1PH 220V (-15%) – 240V (+10%) AC 3PH 380V (-15%) – 440V (+10%)
AC 3PH 380V (-15%) – 440V (+10%)
Inputcurrent(A)
Refer to Rated value ND or LD
Inputfrequency(Hz)
50Hz or 60Hz, allowed range: 47–63Hz
Outputvoltage(V)
AC 3PH 0 – Input Voltage
Outputcurrent(A)
Refer to Rated value ND or LD
Outputpower(kW)
Refer to Rated value ND or LD
Outputfrequency(Hz)
0–400Hz
Speedcontrolprecision
±0.2% (SVC)
Speedfluctuation
±0.3% (SVC)
Torque response
<20ms (SVC)
Torquecontrolprecision
10% (SVC)
Startingtorque
0.5Hz/150% (SVC)
0.25Hz/150% (SVC)
Overload capacity
150% of rated current: 1min (ND), 120% of rated current: 1min (LD) 180% of rated current: 10s (ND), 150% of rated current: 10s (LD) 200% of rated current: 1s (ND), 180% of rated current: 1s (LD)
Frequencysetup mode
Digital setting, analog setting, pulse frequency setting, multi-step, speed running setting, PID setting, MODBUS communication setting
Automaticvoltageregulationfunction
Keep the output voltage constant when grid voltage changes.
Faultprotectionfunction
Fault protection function Provide over 30 kinds of fault protection functions: overcurrent, overvoltage, undervoltage, overtemperature, phase loss and overload, etc.
Speed tracking restart function (Catch-on-the-fly)
–
Realize impact-free starting of the rotating motor
Analoginput
2 inputs: 0–10V / 0–20mA and -10–10V
Analogoutput
1 output: 0–10V / 0–20mA
Digital input
4 common inputs, max. frequency: 1kHz; 1 high speed input, max. frequency: 50kHz