Hitachi X200 Drive – Find comprehensive resources for Hitachi X200 AC drives, including product catalogs, manuals, price list, programming guides, fault, alarm, warnings & software support. Get expert assistance for troubleshooting and optimization.

Features
The Hitachi X200 product line includes more than a dozen inverter models to cover motor sizes from 1/4 horsepower to 10 horsepower, in either 240VAC or 480VAC power input versions. The main features are:
- 200V and 400V class inverters
- US or EU versions available (country-specific input voltage range and default values)
- Built-in RS485 MODBUS RTU as standard
- New current suppressing function
- Sixteen programmable speed levels
- PID control adjusts motor speed automatically to maintain a process variable value
- Integrated CE filter for SFE and HFE versions
The design in Hitachi inverters overcomes many of the traditional trade-offs between speed, torque and efficiency. The performance characteristics are:
- High starting torque of 100% at 6Hz
- Continuous operation at 100% torque within a 1:10 speed range (6/60Hz / 5/50Hz) without motor derating.
- Fan has ON/OFF selection to provide longer life for cooling fan.
A full line of accessories from Hitachi is available to complete your motor application:
- Digital remote operator keypad
- Panel-mount keypad bezel kit and DIN rail mounting adapter (35mm rail size)
- Dynamic braking unit with resistors
- Radio noise filters
3-phase 400V class
Model X200- | European Version | 004HFEF | 007HFEF | 015HFEF | 022HFEF | 030HFEF | 040HFEF | 055HFEF | 075HFEF | ||
US Version | 004HFU | 007HFU | 015HFU | 022HFU | – | 040HFU | 055HFU | 075HFU | |||
Output Ratings | Applicable motor size, 4-pole kW(HP) *1 | 0.4(1/2) | 0.75(1) | 1.5 (2) | 2.2(3) | 3(4) | 4(5) | 5.5(7.5) | 7.5(10) | ||
Rated capacity | 400V | 1.0 | 1.7 | 2.6 | 3.8 | 5.4 | 5.9 | 9.0 | 11.1 | ||
480V | 1.2 | 2.0 | 3.1 | 4.5 | 6.4 | 7.1 | 10.8 | 13.3 | |||
Rated output current (A) *2 | 1.5 | 2.5 | 3.8 | 5.5 | 7.8 | 8.6 | 13.0 | 16.0 | |||
Overload capacity(output current) | 150% for 60 sec. | ||||||||||
Rated output voltage (V) | 3-phase (3-wire) 380 to 480V (corresponding to input voltage) | ||||||||||
Input Rating | Rated input voltage (V) | 3-phase 380 to 480V +10%, -15%, 50/60Hz±5% | |||||||||
Enclosure *4 | IP20 | ||||||||||
Cooling method | Self-cooling | Force ventilation | |||||||||
Integrated EMC filter | -HFEF | EN61800-3 category C2 filter | |||||||||
-HFU | – | ||||||||||
Weight (kg) | -HFEF | 1.5 | 2.3 | 2.4 | 2.4 | 2.4 | 2.4 | 4.2 | 4.2 | ||
-HFU | 1.4 | 2.2 | 2.3 | 2.3 | – | 2.3 | 4.2 | 4.2 |
General Specifications
Item | General Specifications | ||
Control | Control method | Line-to-line sine wave pulse-width modulation (PWM) control | |
Output frequency range *5 | 0.5 to 400Hz | ||
Frequency accuracy *6 | Digital command :±0.01%, Analog command±0.4% (25 ±10˚C) | ||
Frequency setting resolution | Digital: 0.1Hz, Analog: (max frequency)/1000 | ||
Voltage/Frequency Characteristic | V/f control,V/f variable (constant torque, reduced torque) | ||
Acceleration/deceleration time | 0.01 to 3000 sec. (linear, sigmoid), two-stage accel./decel. | ||
Starting torque *7 | 100%/6Hz | ||
Carrier frequency range | 2.0 to 12kHz | ||
Protective functions | Over-current, over-voltage, under-voltage, overload, overheat, ground fault at power-on, input over-voltage, external trip, EEPROM error, CPU error, USP error, Termister error, Driver error, Emergency stop | ||
Input terminal | Specification | 10kohm input impedance, sink/source logic selectable | |
Functions | FW(Forward), RV(Reverse), CF1-CF4(Multispeed command), JG(Jogging), DB(External DC braking), SET(Second motor constants setting), 2CH(Second accel./decel.), FRS(Free-run stop), EXT(External trip), USP(Unattended start protection), SFT(Software lock), AT(Analog input selection), RS(Reset), PTC(Thermistor input) *8, STA(3-wire start), STP(3-wire stop), F/R(3-wire fwd./rev.), PID(PID On/Off), PIDC(PID reset), UP/DWN(Remote-controlled accel./decel.) , UDC(Remote-controlled data clearing), OPE(Operator control), ADD(ADD frequency enable), F- TM(force terminal mode), RDY(quick start enable),S-ST(Special-Set 2nd Motor Data),EMR(Emergency stop), NO(Not selected) | ||
Output signal | Intelligent output terminal | Specification | 27V DC 50mA max open collector output, 1 terminals 1c output 250V AC/30V DC 2.5A relay (AL0, AL1, AL2 terminals) |
Function | RUN(run signal), FA1(Frequency arrival type 1 – constant speed), FA2(Frequency arrival type 2 – over-frequency), OL(overload advance notice signal), OD(Output deviation for PID control), AL(alarm signal), DC(Wire brake detect on analog input), FBV(PID Second Stage Output), NDC(ModBus Network Detection Signal), LOG(Logic Output Function), ODC(Option Card Detection Signal), LOC(Low load) | ||
Analog output terminal | Specification | 0 to 10V DC | |
Function | Analog Frequency monitor, analog current monitor | ||
Operator | Display | Specification | 4-digits 7 segment LEDs |
Function | Parameter setting, output frequency, output current, scaled value of output frequency, trip history, I/O terminal condition, output voltage. Rotation direction, PID Feedback, RON time, Power-on time. | ||
Status LED Interface | Power, Alarm, Run, Prg, Hz and A Potentiometer, RUN, STOP/RESET, UP, DOWN, FUN and STR keys | ||
Operation | Frequency setting | Operator keypad | Up and Down keys / Value settings or analog setting via potentiometer on operator keypad |
External signal | 0 to 10 V DC, 4 to 20 mA | ||
Serial port | RS485 interface (Modbus RTU) | ||
FW/RV Run | Operator Keypad | Run key / Stop key (change FW/RV by function command) | |
External signal | FW Run/Stop (NO contact), RV set by terminal assignment (NC/NO), 3-wire input available | ||
Serial port | RS485 interface (Modbus RTU) | ||
Environment | Operating temperature | -10 to 50˚C(carrier derating required for aambient temperature higher than 40°C), no freezing | |
Storage temperature | -20 to 65˚C | ||
Humidity | 20 to 90% RH | ||
Vibration | 5.9mm/s2 (0.6G) 10 to 55Hz | ||
Location | Altitude 1,000 m or less, indoors (no corrosive gasses or dust) | ||
Other functions | AVR (Automatic Voltage Regulation), V/f characteristic selection, accel./ decel. curve selection, frequency upper/lower limit, 16 stage multispeed, PID control, frequency jump, external frequency input bias start/end, jogging, cooling fan On/Off, trip history etc. | ||
Coating color | Blue | ||
Options | Remote operator with copy function (SRW-0EX), input/output reactors, DC reactors, radio noise filters, braking resistors, braking units, LCR filter, communication cables (ICS-1, 3) |
Note 1: The applicable motor refers to Hitachi standard 3-phase motor (4-pole). When using other motors, care must be taken to prevent the rated motor current (50/60 Hz) from exceeding the rated output current of the inverter.
Note 2: The output voltage decreases as the main supply voltage decreases (except when using the AVR function). In any case, the output voltage cannot exceed the input power supply voltage.
Note 3: The braking torque via capacitive feedback is the average deceleration torque at the shortest deceleration (stopping from 50/60 Hz as indicated). It is not continuous regenerative braking torque. The average decel torque varies with motor loss. This value decreases when operating beyond 50 Hz. If a large regenerative torque is required, the optional regenerative braking resistor should be used.
Note 4: The protection method conforms to JEM 1030.
Note 5: To operate the motor beyond 50/60 Hz, consult the motor manufacturer for the maximum allowable rotation speed. Note 6: The output frequency may exceed the maximum frequency setting (A004 or A204) for automatic stabilization control. Note 7: At the rated voltage when using a Hitachi standard 3-phase, 4pole motor. Note 8: Only terminal 5 is assignable the PTC (thermistor) function.