Performance specifications
Item | XBC/XEC-DN20SU XBC/XEC-DR20SU XBC/XEC-DP20SU | XBC/XEC-DN30SU XBC/XEC-DR30SU XBC/XEC-DP30SU | XBC/XEC-DN40SU XBC/XEC-DR40SU XBC/XEC-DP40SU | XBC/XEC-DN60SU XBC/XEC-DR60SU XBC/XEC-DP60SU |
---|---|---|---|---|
Control method | Repetitive, cyclic, interrupt, constant scan | |||
I/O control method | Refresh mode (Batch processing by scan synchronization), Direct mode by instruction | |||
Programming language | Ladder diagram, Instruction List | |||
Processing speed | 94 ns / Step | |||
Program capacity | 15Kstep / 200KB | |||
Main unit I/O points | 20 (Input:12, Output:8) | 30 (Input:18, Output:12) | 40 (Input:24, Output:16) | 60 (Input:36, Output:24) |
Max. I/O points (Main + Expansion 7 stages) | 244 points | 254 points | 264 points | 284 points |
Total program | 128 | |||
Operation mode | RUN, STOP, DEBUG | |||
Self diagnosis | Detects errors of scan time, memory error, I/O error, battery error, power error, etc. | |||
Program port | RS-232C 1 channel (Loader), USB 1 channel (U-type model) | |||
Retain data at power failure | Latch area setting at basic parameter | |||
Built-in functions | RS-232C / RS-485(2 ch), Pulse catch, Input filter, External interrupt, PID control, High-speed counter, Positioning |
Data memory | |||||
---|---|---|---|---|---|
XBC | XEC | ||||
Data area | P | P0000 ~ P1023F (16,384 points) | Symbolic variable | A | 16KB (Max. 16KB retain setting abailable) |
M | M0000 ~ M1023F (16,384 points) | ||||
K | K0000 ~ K4095F (65,536 points) | Input variable | I | 2KB (%IX 15.15.63) | |
L | L0000 ~ L2047F (32,768 points) | Output variable | Q | 2KB (%QX 15.15.63) | |
F | F0000 ~ F1023F (16,384 points) | Direct variable | M | 8KB (Max. retain setting available) | |
T | 100ms, 10ms, 1ms: T0000 ~ T1023 (1,024) (Adjustable by parameter setting) | R | 20KB (1 block) | ||
C | C0000 ~ C1023 (1,024) | W | 20KB | ||
S | S00.00 ~ S127.99 | Flag variable | F | 2KB | |
D | D0000 ~ D10239 (10,240 word) | K | 8KB | ||
U | U00.00 ~ U0A.31 (Analog data refresh area: 352 word) | L | 4KB | ||
U | 1KB | ||||
Z | Z000 ~ Z127 (128 word) | Flash area | 20KB (2 block) | ||
R | N0000 ~ N10236 (10,240 word) |
* Some products are due in market soon.
Input specification
Item | XBC/XEC-DN20SU XBC/XEC-DR20SU | XBC/XEC-DN30SU XBC/XEC-DR30SU | XBC/XEC-DN40SU XBC/XEC-DR40SU | XBC/XEC-DN60SU XBC/XEC-DR60SU | |
---|---|---|---|---|---|
Input point | 12 points | 18 points | 24 points | 36 points | |
Rated input voltage | DC 24V | ||||
Rated input current | 4mA (Contact point 0~1:16mA, 2~7 :10mA), DN20SU (DN30SU) : 4mA (Contact point 0~7: 10mA) | ||||
Operation voltage range | DC 20.4 ~ 28.8V (Ripple rate < 5%) | ||||
On voltage / On current | DC 19V or more/3mA or more | ||||
Off voltage / Off current | DC 6V or less/1mA or less | ||||
Input resistance | 5.6k (P00 ~ P07 : 2.7k ) | ||||
Response time | Off → On | 1/3/5/10/20/70/100ms (Setting by CPU parameter) Initial value : 3ms | |||
On → Off |
Transistor output specification (Sink/Source type)
Item | XBC/XEC-DN20SU XBC/XEC-DR20SU XBC/XEC-DP20SU | XBC/XEC-DN30SU XBC/XEC-DR30SU XBC/XEC-DP30SU | XBC/XEC-DN40SU XBC/XEC-DR40SU XBC/XEC-DP40SU | XBC/XEC-DN60SU XBC/XEC-DR60SU XBC/XEC-DP60SU | |
---|---|---|---|---|---|
Output point | 8 points | 12 points | 16 points | 24 points | |
Insulation method | Photo coupler insulation | ||||
Rated load voltage | DC 12/24V | ||||
Load voltage range | DC 10.2 ~ 26.4V | ||||
Max. load voltage | 0.5A/1 point, 2A / 1COM | ||||
Off leakage current | 0.1mA or less | ||||
Max. inrush current | 4A/10ms or less | ||||
Max voltage drop (on) | DC 0.4V or less | ||||
Surge absorbe | Zener Diode | ||||
Response time | Off → On | DC 12/24V± 10% (Ripple voltage 4Vp-p or less) | |||
On → Off | 25mA or less (DC 24V connection) |
Relay output specification
Item | XBC/XEC-DR20SU | XBC/XEC-DR30SU | XBC/XEC-DR40SU | XBC/XEC-DR60SU | |
---|---|---|---|---|---|
Output point | 8 points | 12 points | 16 points | 24 points | |
Insulation method | Relay insulation | ||||
Rated load voltage/current | DC 24V 2A/AC 220V 2A (COS = 1), 5A/COM | ||||
Min. load voltage/current | DC 5V/1mA | ||||
Max. load Current | AC 250V, DC 125V | ||||
Off leakage current | 0.1mA (AC 220V, 60Hz) | ||||
Surge absorber | – | ||||
Response time | Off → On | 10ms or less | |||
On → Off | 12ms or less | ||||
Common method ( / COM) | 4 points/COM (P40, P41 : 1 point/COM), (P42 P43 : 2 points/COM) | ||||
Life-cycle | Mechanical | Rated load voltage/Current 10 million times or more | |||
Electrical | AC 220V/1.5A, AC 240V/1A (COS = 0.7) 10 million times or more | ||||
AC 200V/1A, AC 240V/0.5A (COS = 0.35) 10 million times or more | |||||
DC 24V/1A, DC 100V/0.1A (L / R = 7ms) 10 million times or more |
Option I/O
XBO-RTCA | RTC (Real Time Clock), Battery | XBO-AD02A | Voltage/Current, Input 2ch |
---|---|---|---|
XBO-DC04A | DC 24V Input 4 points | XBO-DA02A | Voltage/Current, Output 2ch |
XBO-TN04A | Transistor (Sink) Output 4 points | XBO-AH02A | Voltage/Current, Input 1ch Voltage/Current, Output 1ch |
XBO-RD01A | RTD(Resistance Temperature Detect), Input 1ch | XBO-TC02A | TC (Thermocouple), Input 2ch |
* High speed counter and positioning functions are available in XBO-DC04A and XBO-TN04A, respectively with XGB standard type.