ABB ACS880 Drive Options Code – with the help of type code or part code you can easily identify drive details easily like voltage rating, current rating, power rating, enclosure type & drive option type etc.


Option Code List
Communication protocol adapters
IO Modules
L501 | FIO-01 | 4×DI/O, 2×RO |
L500 | FIO-11 | 3×AI (mA/V), 1×AO (mA), 2×DI/O |
L515 | FEA-03 | 2×F-type option extension slots |
L525 | FAIO-01 | 2×AI(mA/V), 2×AO(mA) |
L526 | FDIO-01 | 3×DI (up to 250 V DC or 230 V AC), 2×RO |
Feedback Devices
DDCS communication option modules
Safety Option Module
Software
Other Option Codes -01
P940 | |
P944 | |
C135 | Selectable option, with plus code |
P905 | |
H356 | |
H381 | |
J414 | Inbuild |
J410 | Selectable option, external, no plus code |
J413 | Selectable option, external, no plus code |
E202 | 7 |
E200 | 10 |
E201 | 12 |
E208 | Selectable option, with plus code |
D150 | 13 |
C132 | 16) |
Q971 | Selectable option, with plus code |
Q973 | Selectable option, with plus code |
Q972 | Selectable option, with plus code |
L521 | Selectable option, with plus code |
Q982 | Selectable option, with plus code |
L537 | Selectable option, with plus code |
Q971 | Selectable option, with plus code |
B056 | IP55 (UL Type 12) |
C131 | Vibration dampers |
C132 | Marine type approval |
C135 | Flange mounting |
C205 | Marine product certification issued by DNV GL |
C206 | Marine product certification issued by the American Bureau of Shipping (ABS) |
C207 | Marine product certification issued by Lloyd’s Register (LR) |
C208 | Marine product certification issued by Registro Italiano Navale (RINA) |
C209 | Marine product certification issued by Bureau Veritas |
C210 | Marine product certification issued by Nippon Kaiji Kyokai (NK) |
D150 | Brake choppers |
E200 | EMC filter for 2nd environment TN (grounded) system, category C3 |
E201 | EMC filter for second environment IT (ungrounded) system, category C3 |
E202 | EMC filter for 1st environment TN (grounded) system, category C2 |
E208 | Common mode filter |
H358 | Cable conduit entry (US/UK). |
0J400 | No control panel |
J425 | ACS-AP-I control panel |
P904 | Extended warranty 24/30 |
P940 | Version for cabinet mounting P940(Drive without front cover and cable box. Includes panel holder, cable between panel holder and control unit, I/O clamp kit and main cable clamp kit in frames R1, R2 and R3, main cable clamp kit in frames R4, R5, R6, R7, R8 and R9. Cannot be selected with P944. |
P944 | Version for cabinet mounting (drive module with front covers but without cable box) |
Q971 | ATEX-certified safe disconnection function |
Q972 | FSO-21 safety functions module |
Q973 | FSO-12 safety functions module |
Q982 | PROFIsafe with FSO-xx safety functions module and FENA-21 Ethernet adapter module |
Q986 | PROFIsafe safety functions module, FSPS-21 |
All Other Option Module
ACS800-11 Options
B056 | IP55 (UL Type 12) |
C135 | Flange mounting |
E200 | EMC filter for 2nd environment TN (grounded) system, category C3 |
E201 | EMC filter for second environment IT (ungrounded) system, category C3 |
E202 | EMC filter for 1st environment TN (grounded) system, category C2 |
E208 | Common mode filter E208 Frames R3 and R6: Built-in as standard. +E208 not shown in the type designation label. Frame R8: +E208 option to be ordered. Installation by customer. |
H358 | Cable conduit entry (US/UK). |
0J400 | No control panel |
J410 | DPMP-01 door mounting kit |
J413 | DPMP-02 door mounting kit (surface mounting) for the panel |
J425 | ACS-AP-I control panel |
P904 | Extended warranty 24/30 |
P931 | Extended warranty 36 months from delivery |
P932 | Extended warranty 60 months from delivery |
P940 | Version for cabinet mounting P940 (Drive module without front covers) |
Q971 | ATEX-certified safe disconnection function |
Q972 | FSO-21 safety functions module |
Q973 | FSO-12 safety functions module |
Q982 | PROFIsafe with FSO-xx safety functions module and FENA-21 Ethernet adapter module |
ACS880-31 Options
B056 | IP55 (UL Type 12) |
C135 | Flange mounting |
E200 | EMC filter for 2nd environment TN (grounded) system, category C3 |
E201 | EMC filter for second environment IT (ungrounded) system, category C3 |
E202 | EMC filter for 1st environment TN (grounded) system, category C2 |
E208 | Common mode filter E208 Frames R3 and R6: Built-in as standard. +E208 not shown in the type designation label. Frame R8: +E208 option to be ordered. Installation by customer. |
H358 | Cable conduit entry (US/UK). |
0J400 | No control panel |
J410 | DPMP-01 door mounting kit |
J413 | DPMP-02 door mounting kit (surface mounting) for the panel |
J425 | ACS-AP-I control panel |
P904 | Extended warranty 24/30 |
P931 | Extended warranty 36 months from delivery |
P932 | Extended warranty 60 months from delivery |
P940 | Version for cabinet mounting P940 (Drive module without front covers) |
Q971 | ATEX-certified safe disconnection function |
Q972 | FSO-21 safety functions module |
Q973 | FSO-12 safety functions module |
Q982 | PROFIsafe with FSO-xx safety functions module and FENA-21 Ethernet adapter module |
ACS880-07CLC drives Options
A004 | 12-pulse supply connection |
A006 | 24-pulse supply connection |
A012 | 50 Hz supply frequency |
A013 | 60 Hz supply frequency |
B054 | IP42 (UL Type 1 Filtered) |
B055 | IP54 (UL Type 12) |
C121 | Marine construction |
C129 | UL Listed (evaluated to both U.S. and Canadian safety requirements). |
C138 | ACS880-1007LC cooling unit as part of line-up |
C139 | ACS880-1007LC cooling unit separate from line-up (stand-alone) |
C140 | Single-pump cooling unit |
C141 | Redundant (twin-pump) cooling unit |
C142 | Pipe connection through bottom |
C144 | Pipe connection on left |
C146 | External cooling circuit suitable for sea water |
C164 | Plinth height 100 mm |
C176 | Door hinges on left |
C179 | Plinth height 200 mm |
C205 | Marine product certification issued by DNV GL |
C206 | Marine product certification issued by the American Bureau of Shipping (ABS) |
C207 | Marine product certification issued by Lloyd’s Register (LR) |
C209 | Marine product certification issued by Bureau Veritas |
C213 | Cooling unit pumps can run simultaneously |
C228 | Marine product certification issued by China Classification Society (CCS) |
C229 | Marine product certification issued by Russian Maritime Register of Shipping (RS) |
C242 | 2-way valve in a dedicated cubicle |
D150 | Brake choppers |
D151 | Brake resistors |
E205 | du/dt filtering |
E210 | EMC/RFI filter for 2nd environment TN (grounded) or IT (ungrounded) system, category C3 |
F271 | Output grounding terminals |
F272 | Internal charging circuit |
G300 | Cabinet and module heating elements (external supply). |
G301 | Cabinet lighting. |
G304 | Control (auxiliary) voltage 115 V AC |
G313 | Output for motor space heater (external supply) |
G314 | Aluminum busbars |
G315 | Tin-plated copper DC busbars |
G316 | Cable supply conductors |
G320 | Control (auxiliary) voltage 230 V AC |
G330 | Halogen-free wiring and materials |
G331 | Emergency stop push button on the door (red) |
G338 | Wire marking class A1 |
G339 | Wire marking class A2 |
G340 | Wire marking class A3 |
G341 | Wire marking class B1 |
G342 | Wire marking class C1 |
H350 | Power cabling entry from bottom. |
H352 | Power cabling exit from bottom. |
H358 | Cable gland plates (3 mm steel, undrilled) |
H359 | Common motor terminal cubicle. |
H364 | Cable gland plates (3 mm aluminum, undrilled) |
H366 | Common output terminals (for inverter modules mounted in the same cubicle). |
H367 | Control cabling through floor of cabinet |
J400 | ACS-AP-W control panel (with Bluetooth) |
K450 | Panel bus (control of several units from one control panel) |
K451 | FDNA-01 DeviceNet™ adapter module |
K454 | FPBA-01 PROFIBUS DP adapter module |
K457 | FCAN-01 CANopen adapter module |
K458 | FSCA-01 RS-485 (Modbus/RTU) adapter module |
K462 | FCNA-01 ControlNet™ adapter module |
K469 | FECA-01 EtherCAT adapter module |
K470 | FEPL-02 Ethernet POWERLINK adapter module |
K473 | FENA-11 Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO protocols |
K475 | FENA-21 Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO protocols, 2-port |
L500 | FIO-11 analog I/O extension module |
L501 | FIO-01 digital I/O extension module |
L502 | FEN-31 HTL incremental encoder interface module |
L503 | FDCO-01 optical DDCS communication adapter module |
L504 | Additional I/O terminal block |
L508 | FDCO-02 optical DDCS communication adapter module |
L509 | RDCO-04 optical DDCS communication for BCU control unit (4xTransmitter/Receiver) |
L525 | FAIO-01 analog I/O extension module |
L526 | FDIO-01 digital I/O extension module |
M600 | Starter for auxiliary motor fan, trip limit 1 … 1.6 A |
M601 | Starter for auxiliary motor fan, trip limit 1.6 … 2.5 A |
M602 | Starter for auxiliary motor fan, trip limit 2.5 … 4 A |
M603 | Starter for auxiliary motor fan, trip limit 4 … 6.3 A |
M604 | Starter for auxiliary motor fan, trip limit 6.3 … 10 A |
M605 | Starter for auxiliary motor fan, trip limit 10…16 A |
M606 | Starter for auxiliary motor fan, trip limit 16…20 A |
M610 | Starter for auxiliary motor fan, trip limit 20…25 A |
M633 | Pump motor in delta connection |
M634 | Pump motor in star connection |
N5000 | Winder control program |
N5050 | Crane control program |
N5100 | Winch control program |
N5200 | PCP (Progressive Cavity Pump) control program |
N5300 | Test bench control program |
N7502 | Control program for synchronous reluctance motors (SynRM) |
N5600 | ESP (Electrical Submersible Pump) control program |
N8010 | IEC 61131-3 application programmability |
P913 | Special color (RAL Classic) |
Q951 | Emergency stop (category 0) with safety relays, by opening the main breaker/contactor |
Q954 | Earth fault monitoring for IT (ungrounded) systems |
Q984 | Emergency stop button monitoring |
ACS880-17 drives options (160-3200 KW)
B054 | IP42 (UL Type 1 Filtered) |
B055 | IP54 (UL Type 12) |
C121 | Marine construction |
C128 | Air inlet through bottom of cabinet. |
C129 | UL Listed (evaluated to both U.S. and Canadian safety requirements) |
C130 | Channeled air outlet |
C132 | Marine type approval. |
C134 | CSA approved. |
C164 | Plinth height 100 mm |
C179 | Plinth height 200 mm |
C180 | Seismic design. |
C199 | Empty 400 mm wide cubicle on left |
C200 | Empty 600 mm wide cubicle on left |
C201 | Empty 800 mm wide cubicle on left |
C205 | Marine product certification issued by DNV GL |
C206 | Marine product certification issued by the American Bureau of Shipping (ABS) |
C207 | Marine product certification issued by Lloyd’s Register (LR) |
C209 | Marine product certification issued by Bureau Veritas |
C228 | Marine product certification issued by China Classification Society (CCS) |
C229 | Marine product certification issued by Russian Maritime Register of Shipping (RS) |
E202 | EMC/RFI filter for 1st environment TN (grounded) system, category C2 |
E205 | du/dt filtering |
E206 | Sine output filter |
F255 | Main circuit breaker |
F259 | Grounding (earthing) switch |
G300 | Cabinet and module heating elements (external supply) |
G301 | Cabinet lighting. |
G307 | Terminals for connecting external control voltage (230 V AC or 115 V AC, eg. UPS) |
G313 | Output for motor space heater (external supply) |
G317 | Supply connection by busbars |
G327 | Ready light on door, white |
G328 | Run light on door, green |
G329 | Fault light on door, red |
G330 | Halogen-free wiring and materials |
G334 | V-meter with selector switch |
G335 | A-meter in one phase |
G340 | Additional wire markings. |
G342 | Additional wire markings. |
G442 | BAMU auxiliary measurement unit |
G453 | Common mode filter temperature monitoring |
H350 | Bottom power cable entry |
H351 | Top power cable entry |
H352 | Motor cabling direction down |
H353 | Motor cabling direction up |
H358 | Cable gland plates (3 mm steel, undrilled) |
H359 | Common motor terminal cubicle |
H366 | Common output terminals (for inverter modules mounted in the same cubicle) |
J425 | ACS-AP-I control panel (without Bluetooth) |
K451 | FDNA-01 DeviceNet™ adapter module |
K454 | FPBA-01 PROFIBUS DP adapter module |
K457 | FCAN-01 CANopen adapter module |
K458 | FSCA-01 RS-485 (Modbus/RTU) adapter module |
K462 | FCNA-01 ControlNet™ adapter module |
K469 | FECA-01 EtherCat adapter module |
K470 | FEPL-02 EtherPOWERLINK adapter module |
K490 | FEIP-21 Ethernet adapter module for EtherNet/IP™ |
K491 | FMBT-21 Ethernet adapter module for Modbus TCP |
K492 | FPNO-21 Ethernet adapter module for PROFINET IO |
L500 | FIO-11 analog I/O extension module |
L501 | FIO-01 digital I/O extension module |
L502 | FEN-31 HTL incremental encoder interface module |
L503 | FDCO-01 optical DDCS communication adapter module |
L504 | Additional I/O terminal block |
L505 | Thermal protection with PTC relays (1 or 2 pcs) |
L506 | Thermal protection with Pt100 relays (2, 3, 5 or 8 pcs) |
L513 | ATEX-certified thermal protection with PTC relays (1 or 2 pcs) |
L514 | ATEX-certified thermal protection with Pt100 relays (3, 5 or 8 pcs) |
L515 | FEA-03 I/O extension adapter |
L516 | FEN-21 resolver interface module |
L517 | FEN-01 TTL incremental encoder interface module |
L518 | FEN-11 TTL absolute encoder interface module |
L521 | FSE-31 pulse encoder interface module |
L525 | FAIO-01 analog I/O extension module |
L526 | FDIO-01 digital I/O extension module |
L536 | FPTC-01 thermistor protection module |
L537 | FPTC-02 ATEX-certified thermistor protection module |
M602 | Starter for auxiliary motor fan, trip limit 2.5 … 4 A |
M603 | Starter for auxiliary motor fan, trip limit 4 … 6.3 A |
M604 | Starter for auxiliary motor fan, trip limit 6.3 … 10 A |
M605 | Starter for auxiliary motor fan, trip limit 10…16 A |
M606 | Starter for auxiliary motor fan, trip limit 16…20 A |
M610 | Starter for auxiliary motor fan, trip limit 20…25 A |
N5000 | Winder control program |
N5050 | Crane control program |
N5100 | Winch control program |
N5200 | PCP (Progressive Cavity Pump) control program |
N5300 | Test bench control program |
N5350 | Cooling tower control program |
N5450 | Override control program |
N5600 | ESP (Electrical Submersible Pump) control program |
N8010 | IEC 61131-3 application programmability |
P902 | Customized |
P904 | Extended warranty (30 months from delivery or 24 months from commissioning) |
N5700 | Position control program |
P909 | Extended warranty (42 months from delivery or 36 months from commissioning) |
P911 | Extended warranty (66 months from delivery or 60 months from commissioning) |
P912 | Seaworthy packaging |
P913 | Special color (RAL Classic) |
P929 | Container packaging |
P948 | Customized extended warranty |
P966 | Special color (other than RAL Classic) |
Q950 | Prevention of unexpected start-up with FSO-xx safety functions module, by activating the Safe torque off function |
Q951 | Emergency stop (category 0) with safety relays, by opening the main breaker/contactor |
Q952 | Emergency stop (category 1) with safety relays, by opening the main breaker/contactor |
Q954 | Earth fault monitoring for IT (ungrounded) systems |
Q957 | Prevention of unexpected start-up with safety relays, by activating the Safe torque off function |
Q963 | Emergency stop (category 0) with safety relays, by activating the Safe torque off function |
Q964 | Emergency stop (category 1) with safety relays, by activating the Safe torque off function |
Q965 | Safely-limited speed with FSO-21 and encoder |
Q971 | ATEX-certified safe disconnection function |
Q972 | FSO-21 safety functions module |
Q973 | FSO-12 safety functions module |
Q978 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by opening the main breaker/contactor |
Q979 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by activating the Safe torque off function |
Q982 | PROFIsafe with FSO-xx safety functions module and FPNO-21 Ethernet adapter module |
Q986 | FSPS-21 PROFIsafe safety functions module |
R700 | Documentation/manuals in English |
R701 | Documentation/manuals in German |
R702 | Documentation/manuals in Italian |
R703 | Documentation/manuals in Dutch |
R704 | Documentation/manuals in Danish |
R705 | Documentation/manuals in Swedish |
R706 | Documentation/manuals in Finnish |
R707 | Documentation/manuals in French |
R708 | Documentation/manuals in Spanish |
R709 | Documentation/manuals in Portuguese |
R711 | Documentation/manuals in Russian |
ACS880-37 Options (160-3200 KW)
B054 | IP42 (UL Type 1 Filtered) |
B055 | IP54 (UL Type 12) |
C121 | Marine construction |
C128 | Air inlet through bottom of cabinet. |
C129 | UL Listed (evaluated to both U.S. and Canadian safety requirements) |
C130 | Channeled air outlet |
C134 | CSA approved. |
C164 | Plinth height 100 mm |
C179 | Plinth height 200 mm |
C180 | Seismic design. |
C199 | Empty 400 mm wide cubicle on left |
C200 | Empty 600 mm wide cubicle on left |
C201 | Empty 800 mm wide cubicle on left |
C205 | Marine product certification issued by DNV GL |
C206 | Marine product certification issued by the American Bureau of Shipping (ABS) |
C207 | Marine product certification issued by Lloyd’s Register (LR) |
C209 | Marine product certification issued by Bureau Veritas |
C228 | Marine product certification issued by China Classification Society (CCS) |
C229 | Marine product certification issued by Russian Maritime Register of Shipping (RS) |
D150 | Brake choppers |
D151 | Brake resistors |
E202 | EMC/RFI filter for 1st environment TN (grounded) system, category C2 |
E205 | du/dt filtering |
E206 | Sine output filter |
F255 | Main circuit breaker |
F259 | Grounding (earthing) switch |
G300 | Cabinet and module heating elements (external supply) |
G301 | Cabinet lighting. |
G307 | Terminals for connecting external control voltage (230 V AC or 115 V AC, eg. UPS) |
G313 | Output for motor space heater (external supply) |
G317 | Supply connection by busbars |
G327 | Ready light on door, white |
G328 | Run light on door, green |
G329 | Fault light on door, red |
G330 | Halogen-free wiring and materials |
G334 | V-meter with selector switch |
G335 | A-meter in one phase |
G340 | Additional wire markings. |
G342 | Additional wire markings. |
G442 | BAMU auxiliary measurement unit |
G453 | Common mode filter temperature monitoring |
H350 | Bottom power cable entry |
H351 | Top power cable entry |
H352 | Motor cabling direction down |
H353 | Motor cabling direction up |
H358 | Cable gland plates (3 mm steel, undrilled) |
H359 | Common motor terminal cubicle |
H366 | Common output terminals (for inverter modules mounted in the same cubicle) |
J425 | ACS-AP-I control panel (without Bluetooth) |
K451 | FDNA-01 DeviceNet™ adapter module |
K454 | FPBA-01 PROFIBUS DP adapter module |
K457 | FCAN-01 CANopen adapter module |
K458 | FSCA-01 RS-485 (Modbus/RTU) adapter module |
K462 | FCNA-01 ControlNet™ adapter module |
K469 | FECA-01 EtherCat adapter module |
K470 | FEPL-02 EtherPOWERLINK adapter module |
K490 | FEIP-21 Ethernet adapter module for EtherNet/IP™ |
K491 | FMBT-21 Ethernet adapter module for Modbus TCP |
K492 | FPNO-21 Ethernet adapter module for PROFINET IO |
L500 | FIO-11 analog I/O extension module |
L501 | FIO-01 digital I/O extension module |
L502 | FEN-31 HTL incremental encoder interface module |
L503 | FDCO-01 optical DDCS communication adapter module |
L504 | Additional I/O terminal block |
L505 | Thermal protection with PTC relays (1 or 2 pcs) |
L506 | Thermal protection with Pt100 relays (2, 3, 5 or 8 pcs) |
L513 | ATEX-certified thermal protection with PTC relays (1 or 2 pcs) |
L514 | ATEX-certified thermal protection with Pt100 relays (3, 5 or 8 pcs) |
L515 | FEA-03 I/O extension adapter |
L516 | FEN-21 resolver interface module |
L517 | FEN-01 TTL incremental encoder interface module |
L518 | FEN-11 TTL absolute encoder interface module |
L521 | FSE-31 pulse encoder interface module |
L525 | FAIO-01 analog I/O extension module |
L526 | FDIO-01 digital I/O extension module |
L536 | FPTC-01 thermistor protection module |
L537 | FPTC-02 ATEX-certified thermistor protection module |
M602 | Starter for auxiliary motor fan, trip limit 2.5 … 4 A |
M603 | Starter for auxiliary motor fan, trip limit 4 … 6.3 A |
M604 | Starter for auxiliary motor fan, trip limit 6.3 … 10 A |
M605 | Starter for auxiliary motor fan, trip limit 10…16 A |
M606 | Starter for auxiliary motor fan, trip limit 16…20 A |
M610 | Starter for auxiliary motor fan, trip limit 20…25 A |
N5000 | Winder control program |
N5050 | Crane control program |
N5100 | Winch control program |
N5200 | PCP (Progressive Cavity Pump) control program |
N5300 | Test bench control program |
N5350 | Cooling tower control program |
N5450 | Override control program |
N5600 | ESP (Electrical Submersible Pump) control program |
N8010 | IEC 61131-3 application programmability |
P902 | Customized |
P904 | Extended warranty (30 months from delivery or 24 months from commissioning) |
N5700 | Position control program |
P909 | Extended warranty (42 months from delivery or 36 months from commissioning) |
P911 | Extended warranty (66 months from delivery or 60 months from commissioning) |
P912 | Seaworthy packaging |
P913 | Special color (RAL Classic) |
P929 | Container packaging |
P948 | Customized extended warranty |
P966 | Special color (other than RAL Classic) |
Q950 | Prevention of unexpected start-up with FSO-xx safety functions module, by activating the Safe torque off function |
Q951 | Emergency stop (category 0) with safety relays, by opening the main breaker/contactor |
Q952 | Emergency stop (category 1) with safety relays, by opening the main breaker/contactor |
Q954 | Earth fault monitoring for IT (ungrounded) systems |
Q957 | Prevention of unexpected start-up with safety relays, by activating the Safe torque off function |
Q963 | Emergency stop (category 0) with safety relays, by activating the Safe torque off function |
Q964 | Emergency stop (category 1) with safety relays, by activating the Safe torque off function |
Q965 | Safely-limited speed with FSO-21 and encoder |
Q971 | ATEX-certified safe disconnection function |
Q972 | FSO-21 safety functions module |
Q973 | FSO-12 safety functions module |
Q978 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by opening the main breaker/contactor |
Q979 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by activating the Safe torque off function |
Q982 | PROFIsafe with FSO-xx safety functions module and FPNO-21 Ethernet adapter module |
Q986 | FSPS-21 PROFIsafe safety functions module |
R700 | Documentation/manuals in English |
R701 | Documentation/manuals in German |
R702 | Documentation/manuals in Italian |
R703 | Documentation/manuals in Dutch |
R704 | Documentation/manuals in Danish |
R705 | Documentation/manuals in Swedish |
R706 | Documentation/manuals in Finnish |
R707 | Documentation/manuals in French |
R708 | Documentation/manuals in Spanish |
R709 | Documentation/manuals in Portuguese |
R711 | Documentation/manuals in Russian |
ACS880-07LC Options
A004 | 12-pulse supply connection |
A012 | 50 Hz supply frequency |
A013 | 60 Hz supply frequency |
B054 | IP42 (UL Type 1 Filtered) |
B055 | IP54 (UL Type 12) |
C121 | Marine construction |
C129 | UL Listed (evaluated to both U.S. and Canadian safety requirements). |
C132 | Marine type approval. |
C164 | Plinth height 100 mm |
C176 | Door hinges on left |
C179 | Plinth height 200 mm |
C205 | Marine product certification issued by DNV GL |
C206 | Marine product certification issued by the American Bureau of Shipping (ABS) |
C207 | Marine product certification issued by Lloyd’s Register (LR) |
C209 | Marine product certification issued by Bureau Veritas |
C228 | Marine product certification issued by China Classification Society (CCS) |
C229 | Marine product certification issued by Russian Maritime Register of Shipping (RS) |
D150 | Brake choppers |
D151 | Brake resistors |
E205 | du/dt filtering |
E210 | EMC/RFI filter for 2nd environment TN (grounded) or IT (ungrounded) system, category C3 |
G300 | Cabinet and module heating elements (external supply). |
G301 | Cabinet lighting. |
G304 | Control (auxiliary) voltage 115 V AC |
G307 | Terminals for connecting external control voltage (230 V AC or 115 V AC, eg. UPS) |
G315 | Tin-plated copper DC busbars |
G320 | Control (auxiliary) voltage 230 V AC |
G330 | Halogen-free wiring and materials |
G338 | Wire marking class A1 |
G339 | Wire marking class A2 |
G340 | Wire marking class A3 |
G341 | Wire marking class B1 |
G342 | Wire marking class C1 |
G344 | Auxiliary voltage transformer |
H350 | Power cabling entry from bottom. |
H351 | Top power cable entry |
H352 | Power cabling exit from bottom. |
H353 | Motor cabling direction up |
H358 | Cable gland plates (3 mm steel, undrilled) |
H364 | Cable gland plates (3 mm aluminum, undrilled) |
H365 | Cable gland plates (6 mm brass, undrilled) |
H367 | Control cabling through floor of cabinet |
H368 | Control cabling through roof of cabinet |
J400 | ACS-AP-W control panel (with Bluetooth) |
K451 | FDNA-01 DeviceNet™ adapter module |
K454 | FPBA-01 PROFIBUS DP adapter module |
K457 | FCAN-01 CANopen adapter module |
K458 | FSCA-01 RS-485 (Modbus/RTU) adapter module |
K462 | FCNA-01 ControlNet™ adapter module |
K469 | FECA-01 EtherCAT adapter module |
K470 | FEPL-02 Ethernet POWERLINK adapter module |
K473 | FENA-11 Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO protocols |
K475 | FENA-21 Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO protocols, 2-port |
K490 | FEIP-21 Ethernet adapter module for EtherNet/IP™ |
K491FMBT-21 | Ethernet adapter module for Modbus TCP |
L505 | Thermal protection with PTC relays (1 or 2 pcs) |
L506 | Thermal protection with Pt100 relays (3, 5 or 8 pcs) |
L513 | ATEX-certified thermal protection with PTC relays (1 or 2 pcs) |
L514 | ATEX-certified thermal protection with Pt100 relays (3, 5 or 8 pcs) |
L536 | FPTC-01 thermistor protection module |
L537 | FPTC-02 ATEX-certified thermistor protection module |
N8010 | IEC 61131-3 application programmability |
P913 | Special color (RAL Classic) |
P966 | Special color (other than RAL Classic) |
Q951 | Emergency stop (category 0) with safety relays, by opening the main breaker/contactor |
Q952 | Emergency stop (category 1) with safety relays, by opening the main breaker/contactor |
Q954 | Earth fault monitoring for IT (ungrounded) systems |
Q963 | Emergency stop (category 0) with safety relays, by activating the Safe torque off function |
Q964 | Emergency stop (category 1) with safety relays, by activating the Safe torque off function |
Q978 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by opening the main breaker/contactor |
Q979 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by activating the Safe torque off function |
Q982 | PROFIsafe with FSO-xx safety functions module and FENA-21 Ethernet adapter module |
Q984 | Emergency stop button monitoring |
Q986 | FSPS-21 PROFIsafe safety functions module |
ACS880-17 drives options (45…400 kW, 60…450 hp)
B054 | IP42 (UL Type 1 Filtered) |
B055 | IP54 (UL Type 12) |
C121 | Marine construction |
C128 | Air inlet through bottom of cabinet. |
C129 | UL Listed (evaluated to both U.S. and Canadian safety requirements) |
C130 | Channeled air outlet |
C132 | Marine type approval. |
C134 | CSA approved. |
C164 | Plinth height 100 mm |
C179 | Plinth height 200 mm |
C180 | Seismic design. |
C196 | Empty 400 mm wide cubicle on right |
C197 | Empty 600 mm wide cubicle on right |
C198 | Empty 800 mm wide cubicle on right |
C199 | Empty 400 mm wide cubicle on left |
C200 | Empty 600 mm wide cubicle on left |
C201 | Empty 800 mm wide cubicle on left |
C205 | Marine product certification issued by DNV GL |
C206 | Marine product certification issued by the American Bureau of Shipping (ABS) |
C207 | Marine product certification issued by Lloyd’s Register (LR) |
C209 | Marine product certification issued by Bureau Veritas |
C228 | Marine product certification issued by China Classification Society (CCS) |
C229 | Marine product certification issued by Russian Maritime Register of Shipping (RS) |
E200 | EMC/RFI filter for 2nd environment TN (grounded) system, category C3 |
E201 | EMC/RFI filter for 2nd environment IT (ungrounded) system, category C3 |
E202 | EMC/RFI filter for 1st environment TN (grounded) system, category C2 |
E205 | du/dt filtering |
E206 | Sine output filter |
E208 | Common mode filtering (standard with frames R6i, R7i, R8i and multiples) |
G300 | Cabinet and module heating elements (external supply) |
G301 | Cabinet lighting. |
G307 | Terminals for connecting external control voltage (230 V AC or 115 V AC, eg. UPS) |
G313 | Output for motor space heater (external supply) |
G327 | Ready light on door, white |
G328 | Run light on door, green |
G329 | Fault light on door, red |
G330 | Halogen-free wiring and materials |
G334 | V-meter with selector switch |
G335 | A-meter in one phase |
G340 | Additional wire markings. |
G342 | Additional wire markings. |
G442 | BAMU auxiliary measurement unit |
H350 | Bottom power cable entry |
H351 | Top power cable entry |
H352 | Motor cabling direction down |
H353 | Motor cabling direction up |
H358 | Cable gland plates (3 mm steel, undrilled) |
J425 | ACS-AP-I control panel (without Bluetooth) |
K451 | FDNA-01 DeviceNet™ adapter module |
K454 | FPBA-01 PROFIBUS DP adapter module |
K457 | FCAN-01 CANopen adapter module |
K458 | FSCA-01 RS-485 (Modbus/RTU) adapter module |
K462 | FCNA-01 ControlNet™ adapter module |
K469 | FECA-01 EtherCat adapter module |
K470 | FEPL-02 EtherPOWERLINK adapter module |
K475 | FENA-21 Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO protocols, 2-port |
K490 | FEIP-21 Ethernet adapter module for EtherNet/IP™ |
K491 | FMBT-21 Ethernet adapter module for Modbus TCP |
K492 | FPNO-21 Ethernet adapter module for PROFINET IO |
L500 | FIO-11 analog I/O extension module |
L501 | FIO-01 digital I/O extension module |
L502 | FEN-31 HTL incremental encoder interface module |
L503 | FDCO-01 optical DDCS communication adapter module |
L504 | Additional I/O terminal block |
L505 | Thermal protection with PTC relays (1 or 2 pcs) |
L506 | Thermal protection with Pt100 relays (2, 3, 5 or 8 pcs) |
L508 | FDCO-02 optical DDCS communication adapter module |
L513 | ATEX-certified thermal protection with PTC relays (1 or 2 pcs) |
L514 | ATEX-certified thermal protection with Pt100 relays (3, 5 or 8 pcs) |
L515 | FEA-03 I/O extension adapter |
L516 | FEN-21 resolver interface module |
L517 | FEN-01 TTL incremental encoder interface module |
L518 | FEN-11 TTL absolute encoder interface module |
L521 | FSE-31 pulse encoder interface module |
L525 | FAIO-01 analog I/O extension module |
L526 | FDIO-01 digital I/O extension module |
L536 | FPTC-01 thermistor protection module |
L537 | FPTC-02 ATEX-certified thermistor protection module |
M600 | Trip limit setting range: 1 … 1.6 A |
M601 | Trip limit setting range: 1.6 … 2.5 A |
M602 | Starter for auxiliary motor fan, trip limit 2.5 … 4 A |
M603 | Starter for auxiliary motor fan, trip limit 4 … 6.3 A |
M604 | Starter for auxiliary motor fan, trip limit 6.3 … 10 A |
M605 | Starter for auxiliary motor fan, trip limit 10…16 A |
N5000 | Winder control program |
N5050 | Crane control program |
N5100 | Winch control program |
N5150 | Decanter/Centrifuge control program |
N5200 | PCP (Progressive Cavity Pump) control program |
N5300 | Test bench control program |
N5350 | Cooling tower control program |
N5450 | Override control program |
N5600 | ESP (Electrical Submersible Pump) control program |
N8010 | IEC 61131-3 application programmability |
P902 | Customized |
P904 | Extended warranty (30 months from delivery or 24 months from commissioning) |
N5700 | Position control program |
P909 | Extended warranty (42 months from delivery or 36 months from commissioning) |
P911 | Extended warranty (66 months from delivery or 60 months from commissioning) |
P912 | Seaworthy packaging |
P913 | Special color (RAL Classic) |
P929 | Container packaging |
P948 | Customized extended warranty |
P952 | Country of origin: Finland |
P966 | Special color (other than RAL Classic) |
Q950 | Prevention of unexpected start-up with FSO-xx safety functions module, by activating the Safe torque off function |
Q951 | Emergency stop (category 0) with safety relays, by opening the main breaker/contactor |
Q952 | Emergency stop (category 1) with safety relays, by opening the main breaker/contactor |
Q954 | Earth fault monitoring for IT (ungrounded) systems |
Q957 | Prevention of unexpected start-up with safety relays, by activating the Safe torque off function |
Q963 | Emergency stop (category 0) with safety relays, by activating the Safe torque off function |
Q964 | Emergency stop (category 1) with safety relays, by activating the Safe torque off function |
Q965 | Safely-limited speed with FSO-21 and encoder |
Q971 | ATEX-certified safe disconnection function |
Q972 | FSO-21 safety functions module |
Q973 | FSO-12 safety functions module |
Q978 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by opening the main breaker/contactor |
Q979 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by activating the Safe torque off function |
Q982 | PROFIsafe with FSO-xx safety functions module and FPNO-21 Ethernet adapter module |
Q986 | FSPS-21 PROFIsafe safety functions module |
R700 | Documentation/manuals in English |
R701 | Documentation/manuals in German |
R702 | Documentation/manuals in Italian |
R703 | Documentation/manuals in Dutch |
R704 | Documentation/manuals in Danish |
R705 | Documentation/manuals in Swedish |
R706 | Documentation/manuals in Finnish |
R707 | Documentation/manuals in French |
R708 | Documentation/manuals in Spanish |
R709 | Documentation/manuals in Portuguese |
R711 | Documentation/manuals in Russian |
R712 | Chinese |
R713 | Polish |
R714 | Turkish |
ACS880-37 drives (45…400 kW, 60…450 hp) Options
B054 | IP42 (UL Type 1 Filtered) |
B055 | IP54 (UL Type 12) |
C121 | Marine construction |
C128 | Air inlet through bottom of cabinet. |
C129 | UL Listed (evaluated to both U.S. and Canadian safety requirements) |
C130 | Channeled air outlet |
C132 | Marine type approval |
C134 | CSA approved. |
C164 | Plinth height 100 mm |
C179 | Plinth height 200 mm |
C180 | Seismic design. |
C196 | Empty 400 mm wide cubicle on right |
C197 | Empty 600 mm wide cubicle on right. |
C198 | Empty 800 mm wide cubicle on right. |
C199 | Empty 400 mm wide cubicle on left |
C200 | Empty 600 mm wide cubicle on left |
C201 | Empty 800 mm wide cubicle on left |
C205 | Marine product certification issued by DNV GL |
C206 | Marine product certification issued by the American Bureau of Shipping (ABS) |
C207 | Marine product certification issued by Lloyd’s Register (LR) |
C209 | Marine product certification issued by Bureau Veritas |
C228 | Marine product certification issued by China Classification Society (CCS) |
C229 | Marine product certification issued by Russian Maritime Register of Shipping (RS) |
D150 | Brake choppers |
D151 | Brake resistors |
E200 | EMC/RFI filter for 2nd environment TN (grounded) system, category C3 |
E201 | EMC/RFI filter for 2nd environment IT (ungrounded) system, category C3 |
E202 | EMC/RFI filter for 1st environment TN (grounded) system, category C2 |
E205 | du/dt filtering |
E206 | Sine output filter |
E208 | Common mode filtering (standard with frames R6i, R7i, R8i and multiples) |
G300 | Cabinet and module heating elements (external supply) |
G301 | Cabinet lighting. |
G307 | Terminals for connecting external control voltage (230 V AC or 115 V AC, eg. UPS) |
G313 | Output for motor space heater (external supply) |
G327 | Ready light on door, white |
G328 | Run light on door, green |
G329 | Fault light on door, red |
G330 | Halogen-free wiring and materials |
G334 | V-meter with selector switch |
G335 | A-meter in one phase |
G340 | Additional wire markings. |
G342 | Additional wire markings. |
H350 | Bottom power cable entry |
H351 | Top power cable entry |
H352 | Motor cabling direction down |
H353 | Motor cabling direction up |
H358 | Cable gland plates (3 mm steel, undrilled) |
J425 | ACS-AP-I control panel (without Bluetooth) |
K451 | FDNA-01 DeviceNet™ adapter module |
K454 | FPBA-01 PROFIBUS DP adapter module |
K457 | FCAN-01 CANopen adapter module |
K458 | FSCA-01 RS-485 (Modbus/RTU) adapter module |
K462 | FCNA-01 ControlNet™ adapter module |
K469 | FECA-01 EtherCat adapter module |
K470 | FEPL-02 EtherPOWERLINK adapter module |
K475 | FENA-21 Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO protocols, 2-port |
K490 | FEIP-21 Ethernet adapter module for EtherNet/IP™ |
K491 | FMBT-21 Ethernet adapter module for Modbus TCP |
K492 | FPNO-21 Ethernet adapter module for PROFINET IO |
L500 | FIO-11 analog I/O extension module |
L501 | FIO-01 digital I/O extension module |
L502 | FEN-31 HTL incremental encoder interface module |
L503 | FDCO-01 optical DDCS communication adapter module |
L504 | Additional I/O terminal block |
L505 | Thermal protection with PTC relays (1 or 2 pcs) |
L506 | Thermal protection with Pt100 relays (2, 3, 5 or 8 pcs) |
L508 | FDCO-02 optical DDCS communication adapter module |
L513 | ATEX-certified thermal protection with PTC relays (1 or 2 pcs) |
L514 | ATEX-certified thermal protection with Pt100 relays (3, 5 or 8 pcs) |
L515 | FEA-03 I/O extension adapter |
L516 | FEN-21 resolver interface module |
L517 | FEN-01 TTL incremental encoder interface module |
L518 | FEN-11 TTL absolute encoder interface module |
L521 | FSE-31 pulse encoder interface module |
L525 | FAIO-01 analog I/O extension module |
L526 | FDIO-01 digital I/O extension module |
L536 | FPTC-01 thermistor protection module |
L537 | FPTC-02 ATEX-certified thermistor protection module |
M600 | Trip limit setting range: 1 … 1.6 A |
M601 | Trip limit setting range: 1.6 … 2.5 A |
M602 | Starter for auxiliary motor fan, trip limit 2.5 … 4 A |
M603 | Starter for auxiliary motor fan, trip limit 4 … 6.3 A |
M604 | Starter for auxiliary motor fan, trip limit 6.3 … 10 A |
M605 | Starter for auxiliary motor fan, trip limit 10…16 A |
N5000 | Winder control program |
N5050 | Crane control program |
N5100 | Winch control program |
N5200 | PCP (Progressive Cavity Pump) control program |
N5300 | Test bench control program |
N5350 | Cooling tower control program |
N5450 | Override control program |
N5600 | ESP (Electrical Submersible Pump) control program |
N8010 | IEC 61131-3 application programmability |
N7502 | Control program for synchronous reluctance motors (SynRM) |
P902 | Customized |
P904 | Extended warranty (30 months from delivery or 24 months from commissioning) |
N5700 | Position control program |
P909 | Extended warranty (42 months from delivery or 36 months from commissioning) |
P911 | Extended warranty (66 months from delivery or 60 months from commissioning) |
P912 | Seaworthy packaging |
P913 | Special color (RAL Classic) |
P929 | Container packaging |
P948 | Customized extended warranty |
P966 | Special color (other than RAL Classic) |
Q950 | Prevention of unexpected start-up with FSO-xx safety functions module, by activating the Safe torque off function |
Q951 | Emergency stop (category 0) with safety relays, by opening the main breaker/contactor |
Q952 | Emergency stop (category 1) with safety relays, by opening the main breaker/contactor |
Q954 | Earth fault monitoring for IT (ungrounded) systems |
Q957 | Prevention of unexpected start-up with safety relays, by activating the Safe torque off function |
Q963 | Emergency stop (category 0) with safety relays, by activating the Safe torque off function |
Q964 | Emergency stop (category 1) with safety relays, by activating the Safe torque off function |
Q965 | Safely-limited speed with FSO-21 and encoder |
Q971 | ATEX-certified safe disconnection function |
Q972 | FSO-21 safety functions module |
Q973 | FSO-12 safety functions module |
Q978 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by opening the main breaker/contactor |
Q979 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by activating the Safe torque off function |
Q982 | PROFIsafe with FSO-xx safety functions module and FPNO-21 Ethernet adapter module |
Q986 | FSPS-21 PROFIsafe safety functions module |
R700 | Documentation/manuals in English |
R701 | Documentation/manuals in German |
R702 | Documentation/manuals in Italian |
R703 | Documentation/manuals in Dutch |
R704 | Documentation/manuals in Danish |
R705 | Documentation/manuals in Swedish |
R706 | Documentation/manuals in Finnish |
R707 | Documentation/manuals in French |
R708 | Documentation/manuals in Spanish |
R709 | Documentation/manuals in Portuguese |
R711 | Documentation/manuals in Russian |
R712 | Chinese |
R713 | Polish |
R714 | Turkish |
ACS880-17LC drives
A012 | 50 Hz supply frequency |
A013 | 60 Hz supply frequency |
B054 | IP42 (UL Type 1 Filtered) |
B055 | IP54 (UL Type 12) |
C121 | Marine construction |
C132 | Marine type approval. |
C138 | ACS880-1007LC cooling unit as part of line-up |
C139 | ACS880-1007LC cooling unit separate from line-up (stand-alone) |
C140 | Single-pump cooling unit |
C141 | Redundant (twin-pump) cooling unit |
C142 | Pipe connection through bottom |
C144 | Pipe connection on left |
C145 | ANSI flange pipe connection |
C146 | External cooling circuit suitable for sea water |
C164 | Plinth height 100 mm |
C176 | Door hinges on left |
C179 | Plinth height 200 mm |
C205 | Marine product certification issued by DNV GL |
C206 | Marine product certification issued by the American Bureau of Shipping (ABS) |
C207 | Marine product certification issued by Lloyd’s Register (LR) |
C209 | Marine product certification issued by Bureau Veritas |
C213 | Cooling unit pumps can run simultaneously |
C228 | Marine product certification issued by China Classification Society (CCS) |
C229 | Marine product certification issued by Russian Maritime Register of Shipping (RS) |
C242 | 2-way valve in a dedicated cubicle |
E205 | du/dt filtering |
F271 | Output grounding terminals |
F253 | Disconnect switch |
G300 | Cabinet and module heating elements (external supply). |
G301 | Cabinet lighting. |
G304 | Control (auxiliary) voltage 115 V AC |
G307 | Terminals for connecting external control voltage (230 V AC or 115 V AC, eg. UPS) |
G313 | Output for motor space heater (external supply) |
G314 | Aluminum busbars |
G315 | Tin-plated copper DC busbars |
G316 | Cable supply conductors |
G320 | Control (auxiliary) voltage 230 V AC |
G330 | Halogen-free wiring and materials |
G332 | Electrical disconnect push button on the door (black, opens main contactor / ACB) |
G333 | kW-meter on door |
G334 | V-meter with selector switch |
G335 | A-meter in one phase |
G338 | Wire marking class A1 |
G339 | Wire marking class A2 |
G340 | Wire marking class A3 |
G341 | Wire marking class B1 |
G342 | Wire marking class C1 |
G344 | Auxiliary voltage transformer |
G432 | Frequency monitoring device. Only for installation altitudes up to 2000 meters (6561 ft). |
H359 | Common motor terminal cubicle. |
H364 | Cable gland plates (3 mm aluminum, undrilled) |
H367 | Control cabling through floor of cabinet |
J400 | ACS-AP-W control panel (with Bluetooth) |
K450 | Panel bus (control of several units from one control panel) |
K451 | FDNA-01 DeviceNet™ adapter module |
K452 | FLON-01 LonWorks® adapter module |
K454 | FPBA-01 PROFIBUS DP adapter module |
K457 | FCAN-01 CANopen adapter module |
K458 | FSCA-01 RS-485 (Modbus/RTU) adapter module |
K462 | FCNA-01 ControlNet™ adapter module |
K469 | FECA-01 EtherCAT adapter module |
K470 | FEPL-02 Ethernet POWERLINK adapter module |
K473 | FENA-11 Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO protocols |
K475 | FENA-21 Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO protocols, 2-port |
L500 | FIO-11 analog I/O extension module |
L501 | FIO-01 digital I/O extension module |
L502 | FEN-31 HTL incremental encoder interface module |
L505 | Thermal protection with PTC relays (1 or 2 pcs). |
4M601 | Trip limit setting range: 1.6 … 2.5 A |
M602 | Trip limit setting range: 2.5 … 4 A |
M603 | Starter for auxiliary motor fan, trip limit 4 … 6.3 A |
M604 | Starter for auxiliary motor fan, trip limit 6.3 … 10 A |
M605 | Starter for auxiliary motor fan, trip limit 10…16 A |
M606 | Starter for auxiliary motor fan, trip limit 16…20 A |
N5000 | Winder control program |
N5050 | Crane control program |
N5100 | Winch control program |
N5200 | PCP (Progressive Cavity Pump) control program |
N5300 | Test bench control program |
N7502 | Control program for synchronous reluctance motors (SynRM) |
N5600 | ESP (Electrical Submersible Pump) control program |
N8010 | IEC 61131-3 application programmability |
P913 | Special color (RAL Classic) |
Q951 | Emergency stop (category 0) with safety relays, by opening the main breaker/contactor |
Q952 | Emergency stop (category 1) with safety relays, by opening the main breaker/contactor |
Q957 | Prevention of unexpected start-up with safety relays, by activating the Safe torque off function. Only for installation altitudes up to 2000 meters (6561 ft). |
Q963 | Emergency stop (category 0) with safety relays, by activating the Safe torque off function |
Q964 | Emergency stop (category 1) with safety relays, by activating the Safe torque off function |
Q965 | Safely-limited speed with FSO-21 and encoder |
Q966 | Safely-limited speed without encoder |
Q971 | ATEX-certified safe disconnection function |
Q972 | FSO-21 safety functions module |
Q973 | FSO-12 safety functions module |
Q978 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by opening the main breaker/contactor |
Q979 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by activating the Safe torque off function |
Q982 | PROFIsafe with FSO-xx safety functions module and FENA-21 Ethernet adapter module |
Q984 | Emergency stop button monitoring |
R715 | Complete documentation, user manuals in memory stick |
R716 | Hard copies of documentation |
R717 | Second set of hard copies of documentation |
ACS880-37LC drives
A012 | 50 Hz supply frequency |
A013 | 60 Hz supply frequency |
B054 | IP42 (UL Type 1 Filtered) |
B055 | IP54 (UL Type 12) |
C121 | Marine construction |
C132 | Marine type approval. |
C138 | ACS880-1007LC cooling unit as part of line-up |
C139 | ACS880-1007LC cooling unit separate from line-up (stand-alone) |
C140 | Single-pump cooling unit |
C141 | Redundant (twin-pump) cooling unit |
C142 | Pipe connection through bottom |
C143 | Pipe connection on right |
C144 | Pipe connection on left |
C145 | ANSI flange pipe connection |
C146 | External cooling circuit suitable for sea water |
C164 | Plinth height 100 mm |
C176 | Door hinges on left |
C179 | Plinth height 200 mm |
C205 | Marine product certification issued by DNV GL |
C206 | Marine product certification issued by the American Bureau of Shipping (ABS) |
C207 | Marine product certification issued by Lloyd’s Register (LR) |
C209 | Marine product certification issued by Bureau Veritas |
C213 | Cooling unit pumps can run simultaneously |
C228 | Marine product certification issued by China Classification Society (CCS) |
C229 | Marine product certification issued by Russian Maritime Register of Shipping (RS) |
C242 | 2-way valve in a dedicated cubicle |
D150 | Brake choppers |
D151 | Brake resistors |
E205 | du/dt filtering |
F271 | Output grounding terminals |
F253 | Disconnect switch |
G300 | Cabinet and module heating elements (external supply). |
G301 | Cabinet lighting. |
G304 | Control (auxiliary) voltage 115 V AC |
G307 | Terminals for connecting external control voltage (230 V AC or 115 V AC, eg. UPS) |
G313 | Output for motor space heater (external supply) |
G314 | Aluminum busbars |
G315 | Tin-plated copper DC busbars |
G316 | Cable supply conductors |
G320 | Control (auxiliary) voltage 230 V AC |
G330 | Halogen-free wiring and materials |
G332 | Electrical disconnect push button on the door (black, opens main contactor / ACB) |
G333 | kW-meter on door |
G334 | V-meter with selector switch |
G335 | A-meter in one phase |
G338 | Wire marking class A1 |
G339 | Wire marking class A2 |
G340 | Wire marking class A3 |
G341 | Wire marking class B1 |
G342 | Wire marking class C1 |
G344 | Auxiliary voltage transformer |
G432 | Frequency monitoring device. Only for installation altitudes up to 2000 meters (6561 ft). |
H353 | Motor cabling direction up |
H359 | Common motor terminal cubicle. |
H364 | Cable gland plates (3 mm aluminum, undrilled) |
H367 | Control cabling through floor of cabinet |
J400 | ACS-AP-W control panel (with Bluetooth) |
K450 | Panel bus (control of several units from one control panel) |
K451 | FDNA-01 DeviceNet™ adapter module |
K452 | FLON-01 LonWorks® adapter module |
K454 | FPBA-01 PROFIBUS DP adapter module |
K457 | FCAN-01 CANopen adapter module |
K458 | FSCA-01 RS-485 (Modbus/RTU) adapter module |
K462 | FCNA-01 ControlNet™ adapter module |
K469 | FECA-01 EtherCAT adapter module |
K470 | FEPL-02 Ethernet POWERLINK adapter module |
K473 | FENA-11 Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO protocols |
K475 | FENA-21 Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO protocols, 2-port |
L500 | FIO-11 analog I/O extension module |
L501 | FIO-01 digital I/O extension module |
L502 | FEN-31 HTL incremental encoder interface module |
L505 | Thermal protection with PTC relays (1 or 2 pcs). |
4M601 | Trip limit setting range: 1.6 … 2.5 A |
M602 | Trip limit setting range: 2.5 … 4 A |
M603 | Starter for auxiliary motor fan, trip limit 4 … 6.3 A |
M604 | Starter for auxiliary motor fan, trip limit 6.3 … 10 A |
M605 | Starter for auxiliary motor fan, trip limit 10…16 A |
M606 | Starter for auxiliary motor fan, trip limit 16…20 A |
N5000 | Winder control program |
N5050 | Crane control program |
N5100 | Winch control program |
N5200 | PCP (Progressive Cavity Pump) control program |
N5300 | Test bench control program |
N7502 | Control program for synchronous reluctance motors (SynRM) |
N5600 | ESP (Electrical Submersible Pump) control program |
N8010 | IEC 61131-3 application programmability |
P913 | Special color (RAL Classic) |
Q951 | Emergency stop (category 0) with safety relays, by opening the main breaker/contactor |
Q952 | Emergency stop (category 1) with safety relays, by opening the main breaker/contactor |
Q957 | Prevention of unexpected start-up with safety relays, by activating the Safe torque off function. Only for installation altitudes up to 2000 meters (6561 ft). |
Q963 | Emergency stop (category 0) with safety relays, by activating the Safe torque off function |
Q964 | Emergency stop (category 1) with safety relays, by activating the Safe torque off function |
Q965 | Safely-limited speed with FSO-21 and encoder |
Q966 | Safely-limited speed without encoder |
Q971 | ATEX-certified safe disconnection function |
Q972 | FSO-21 safety functions module |
Q973 | FSO-12 safety functions module |
Q978 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by opening the main breaker/contactor |
Q979 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by activating the Safe torque off function |
Q982 | PROFIsafe with FSO-xx safety functions module and FENA-21 Ethernet adapter module |
Q984 | Emergency stop button monitoring |
R715 | Complete documentation, user manuals in memory stick |
R716 | Hard copies of documentation |
R717 | Second set of hard copies of documentation |
ACS880-07 Option
A004 | 12-pulse supply connection |
B054 | IP42 (UL Type 1 Filtered) |
B055 | IP54 (UL Type 12) |
C121 | Marine construction |
C128 | Air inlet through bottom of cabinet |
C129 | UL Listed (evaluated to both U.S. and Canadian safety requirements). |
C130 | Channeled air outlet. |
C132 | Marine type approval. |
C134 | CSA approved. |
C164 | Plinth height 100 mm |
C179 | Plinth height 200 mm |
C180 | Seismic design. |
C196 | Empty 400 mm wide cubicle on right |
C197 | Empty 600 mm wide cubicle on right |
C198 | Empty 800 mm wide cubicle on right. |
C199 | Empty 400 mm wide cubicle on left |
C200 | Empty 600 mm wide cubicle on left |
C201 | Empty 800 mm wide cubicle on left |
C205 | Marine product certification issued by DNV GL |
C206 | Marine product certification issued by the American Bureau of Shipping (ABS) |
C207 | Marine product certification issued by Lloyd’s Register (LR) |
C209 | Marine product certification issued by Bureau Veritas |
C228 | Marine product certification issued by China Classification Society (CCS) |
C229 | Marine product certification issued by Russian Maritime Register of Shipping (RS) |
D150 | Brake choppers |
D151 | Brake resistors |
E200 | EMC/RFI filter for 2nd environment TN (grounded) system, category C3 |
E201 | EMC/RFI filter for 2nd environment IT (ungrounded) system, category C3 For frame R6 690 V: EMC/RFI filter for 2nd environment IT (ungrounded) system, category C4 |
E202 | EMC/RFI filter for 1st environment TN (grounded) system, category C2 |
E205 | du/dt filtering |
E206 | Sine output filter |
E208 | Common mode filtering (standard with frames R6i, R7i, R8i and multiples) |
F250 | Main (line) contactor |
F255 | Main (air) circuit breaker |
F277 | Flange-mounted switch for MCCB |
F289 | MCCB circuit breaker |
G300 | Cabinet and module heating elements (external supply). |
G301 | Cabinet lighting. |
G307 | Terminals for connecting external control voltage (230 V AC or 115 V AC, eg. UPS) |
G313 | Output for motor space heater (external supply) |
G327 | Ready light on door, white |
G328 | Run light on door, green |
G329 | Fault light on door, red |
G330 | Halogen-free wiring and materials |
G334 | V-meter with selector switch |
G335 | A-meter in one phase |
G340 | Additional wire markings |
G342 | Additional wire markings |
H350 | Power cabling entry from bottom. |
H351 | Top power cable entry |
H352 | Power cabling exit from bottom. |
H353 | Top exit |
H356 | DC cable connection busbars |
H358 | Cable conduit entry (US/UK) |
K451 | FDNA-01 DeviceNet™ adapter module |
K454 | FPBA-01 PROFIBUS DP adapter module |
K457 | FCAN-01 CANopen adapter module |
K458 | FSCA-01 RS-485 (Modbus/RTU) adapter module |
K462 | FCNA-01 ControlNet™ adapter module |
K469 | FECA-01 EtherCAT adapter module |
K470 | FEPL-02 Ethernet POWERLINK adapter module |
K473 | FENA-11 Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO protocols |
K475 | FENA-21 Ethernet adapter module for EtherNet/IP™, Modbus TCP and PROFINET IO protocols, 2-port |
K490 | FEIP-21 Ethernet adapter module for EtherNet/IP™ |
K491FMBT-21 | Ethernet adapter module for Modbus TCP |
L505 | Thermal protection with PTC relays (1 or 2 pcs) |
L506 | Thermal protection with Pt100 relays (3, 5 or 8 pcs) |
L513 | ATEX-certified thermal protection with PTC relays (1 or 2 pcs) |
L514 | ATEX-certified thermal protection with Pt100 relays (3, 5 or 8 pcs) |
L536 | FPTC-01 thermistor protection module |
L537 | FPTC-02 ATEX-certified thermistor protection module |
M600 | Starter for auxiliary motor fan, trip limit 1 … 1.6 A |
M601 | Starter for auxiliary motor fan, trip limit 1.6 … 2.5 A |
M602 | Trip limit setting range: 2.5 … 4 A |
M603 | Trip limit setting range: 4 … 6.3 A |
M604 | Trip limit setting range: 6.3 … 10 A |
M605 | Trip limit setting range: 10…16 A |
N5000 | Winder control program |
N5050 | Crane control program |
N5100 | Winch control program |
N5200 | PCP/ESP control program |
N5300 | Test bench control program |
N5450 | Override control program |
N8010 | IEC 61131-3 application programmability |
P902 | Customized |
P904 | Extended warranty |
P909 | Extended warranty (42 months from delivery or 36 months from commissioning) |
P911 | Extended warranty (66 months from delivery or 60 months from commissioning) |
P912 | Seaworthy packaging |
P913 | Special color |
P947 | Safety data calculation and validation for tailored safety functions |
P948 | Customized extended warranty |
P952 | Country of origin: Finland |
P966 | Special color (other than RAL Classic) |
Q950 | Prevention of unexpected start-up with FSO-xx safety functions module, by activating the Safe torque off function |
Q951 | Emergency stop (category 0) with safety relays, by opening the main breaker/contactor |
Q952 | Emergency stop (category 1) with safety relays, by opening the main breaker/contactor |
Q954 | Earth fault monitoring for IT (ungrounded) systems |
Q957 | Prevention of unexpected start-up with safety relays, by activating the Safe torque off function |
Q963 | Emergency stop (category 0) with safety relays, by activating the Safe torque off function |
Q964 | Emergency stop (category 1) with safety relays, by activating the Safe torque off function |
Q965 | Safely-limited speed with FSO-21 and encoder |
Q971 | ATEX-certified safe disconnection function |
Q972 | FSO-21 safety functions module |
Q973 | FSO-12 safety functions module |
Q978 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by opening the main breaker/contactor |
Q979 | Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by activating the Safe torque off function |
Q982 | PROFIsafe with FSO-xx safety functions module and FENA-21 Ethernet adapter module |
Q986 | FSPS-21 PROFIsafe safety functions module |











Other Useful Links – ABB ACS880 Drive

Dedicated Free Forum & Chat Support
Get all fault, alarm, warning & error code solution at one place. Ask expert for support regarding programming, parameter & application selection and all information.
Other ABB Drive Series
Get all information of other ABB drives like product information, price list, programming, fault & error codes and all other information.


ABB Drive Price List
ABB Drives Price List – compare drives by specification, rating, features & advance options. Get all information about drive like features, function, specification compare all drive. Here you can easily find drive as per application & features.

Get free drive training, learn more about drive like –
What is drive ?
Types of drive
Working
Drive programming and many more
Get more information about Industrial Automation
Get all information about industrial automation like electronics & electrical basics, tools and test equipment’s, troubleshoot fault, learn repairing at card level & component level, learn more about devices like drives, PLC’s, soft-starter, sensor and many more.

ABB ACS880 Drive Options Code
Powerful Tool for product finder – Search all industrial product, search by brand, search by series, search by part no. search by specification. Compare product by specification & options. Product filter – easy tool to filter your product for best match. Powerful product finder tool get your application compatible product with all solution like document & catalog, programming error and fault solution
Industrial Automation Forum – Forum with all your need, get support regarding application selection, application solution, product finder, product related problem solution. If any fault coming in your product simple search and get solution. If any fault or error not showing simple ask to our expert for best solution. Here you can search all fault, alarm & warning solution just simple search. No need to download multiple manual for multiple product.